Important! 

Safety Instructions are defined as follows:

WARNING: IMPORTANT SAFETY 
INFORMATION FOR HAZARDS THAT 
MIGHT CAUSE SERIOUS INJURY.

CAUTION: Important information for 
preventing damage to the Eclipse 5.

Note: Information needing special attention.

Indications for Use

WARNING: IT IS VERY IMPORTANT 
TO SELECT ONLY THE PRESCRIBED 
LEVEL OF OXYGEN. DO NOT CHANGE 
THE FLOW SELECTION UNLESS YOU 
HAVE BEEN DIRECTED TO DO SO BY A 
LICENSED CLINICIAN. THE PORTABLE 
OXYGEN CONCENTRATOR MAY BE 
USED DURING SLEEP UNDER THE 
RECOMMENDATION OF A QUALIFIED 
CLINICIAN.

WARNING: TO ENSURE RECEIVING THE 
THERAPEUTIC AMOUNT OF OXYGEN DELIVERY 
ACCORDING TO YOUR MEDICAL CONDITION, 
ECLIPSE 5 MUST BE USED ONLY AFTER ONE OR 
MORE SETTINGS HAVE BEEN INDIVIDUALLY 
DETERMINED OR PRESCRIBED FOR YOU AT YOUR 
SPECIFIC ACTIVITY LEVELS. ECLIPSE 5 MUST BE 
USED WITH THE SPECIFIC COMBINATION OR 
PARTS AND ACCESSORIES THAT ARE IN LINE 
WITH THE SPECIFICATION OF THE CONCENTRA-
TOR MANUFACTURER AND THAT WERE USED 
WHILE YOUR SETTINGS WERE DETERMINED.
WARNING: FEDERAL (USA) LAW RESTRICTS THIS 
DEVICE TO SALE OR RENTAL BY ORDER OF A 
PHYSICIAN OR OTHER LICENSED HEALTH CARE 
PROVIDER.
WARNING: THIS UNIT IS NOT TO BE USED FOR 
LIFE SUPPORT. GERIATRIC, PEDIATRIC, OR ANY 
OTHER PATIENT UNABLE TO COMMUNICATE 
DISCOMFORT CAN REQUIRE ADDITIONAL 
MONITORING AND/OR A DISTRIBUTED ALARM 
SYSTEM TO CONVEY THE INFORMATION ABOUT 
THE DISCOMFORT AND OR THE MEDICAL 
URGENCY TO THE RESPONSIBLE CARE GIVER TO 
AVOID HARM. PATIENTS WITH HEARING AND/OR 
SIGHT IMPAIRMENT(S) MAY NEED ASSISTANCE 
WITH MONITORING ALARMS.

Contraindications for Use

WARNING: IN CERTAIN CIRCUM-
STANCES, THE USE OF NON-PRE-
SCRIBED OXYGEN CAN BE HAZARD-
OUS. THIS DEVICE SHOULD ONLY 
BE USED WHEN PRESCRIBED BY A 
PHYSICIAN.

WARNING: NOT FOR USE IN THE PRESENCE OF 
FLAMMABLE ANESTHETICS.
WARNING: AS WITH ANY ELECTRICALLY 
POWERED DEVICE, THE USER MAY EXPERIENCE 
PERIODS OF NON-OPERATION AS A RESULT OF 
ELECTRICAL POWER INTERRUPTION, OR THE 
NEED TO HAVE THE ECLIPSE 5 SERVICED BY A 
QUALIFIED TECHNICIAN. THE ECLIPSE 5 IS NOT 
APPROPRIATE FOR ANY PATIENT WHO WOULD 
EXPERIENCE ADVERSE HEALTH CONSEQUENCES 
AS THE RESULT OF SUCH TEMPORARY INTER-
RUPTION.

Safety Guidelines

WARNING: NO MODIFICATION OF 
THIS EQUIPMENT IS PERMITTED

WARNING: THE MANUFACTURER RECOMMENDS 
AN ALTERNATE SOURCE OF SUPPLEMENTAL 
OXYGEN IN THE EVENT OF A POWER OUTAGE, 
ALARM CONDITION, OR MECHANICAL FAILURE. 
CONSULT YOUR PHYSICIAN OR EQUIPMENT 
PROVIDER FOR THE TYPE OF RESERVE SYSTEM 
REQUIRED. 
WARNING: THIS DEVICE SUPPLIES HIGH-CON-
CENTRATION OXYGEN THAT PROMOTES RAPID 
BURNING. DO NOT ALLOW SMOKING OR OPEN 
FLAMES WITHIN TWO (2) METERS OF (1) THIS 
DEVICE, OR (2) ANY OXYGEN-CARRYING ACCES-
SORY. FAILURE TO OBSERVE THIS WARNING CAN 
RESULT IN SEVERE FIRE, PROPERTY DAMAGE, 
AND/OR CAUSE PHYSICAL INJURY OR DEATH.
WARNING: DO NOT OPERATE UNIT IN A RE-
STRICTED OR CONFINED SPACE (I.E., A SMALL 
CASE OR HANDBAG) WHERE VENTILATION CAN 
BE LIMITED. THIS CAN CAUSE THE OXYGEN 
CONCENTRATOR TO OVERHEAT AND IMPAIR 
PERFORMANCE.

Содержание Eclipse 5

Страница 1: ...Eclipse 5 with autoSAT User Manual English...

Страница 2: ...ial Number Reg 2498 This way up Reg 0623 Fragile handle with care Reg 0621 Keep away from rain keep dry Reg 0626 Stacking limit by number Reg 2403 ISO 7010 Graphical symbols Safety colors and safety s...

Страница 3: ...sieve This material separates the oxygen from the nitrogen and allows only the oxygen to pass through The result is a flow of high concentration oxygen delivered to the user The Eclipse 5 combines ad...

Страница 4: ...al Become familiar with the key features of the Eclipse 5 and the User Control Panel Eclipse 5 AC Power Supply DC Power Supply Universal Cart Power Cartridge battery FRONT Control Panel Handle Oxygen...

Страница 5: ...nd Indicator The button toggles between Contin uous Flow and Pulse Dose Mode The Pulse Dose Mode activates autoSAT Technology and allows a significant increase in the operating time while powered by t...

Страница 6: ...back and forth between continuous flow and pulse dose modes In Continuous Flow Mode the oxygen is provided at a constant flow rate between 0 5 and 3 0 LPM In Pulse Dose Mode ox ygen is supplied in a...

Страница 7: ...ION ABOUT THE DISCOMFORT AND OR THE MEDICAL URGENCY TO THE RESPONSIBLE CARE GIVER TO AVOID HARM PATIENTS WITH HEARING AND OR SIGHT IMPAIRMENT S MAY NEED ASSISTANCE WITH MONITORING ALARMS Contraindicat...

Страница 8: ...ENTRATOR THE BATTERY MUST ALSO BE REMOVED FROM THE DEVICE AND PACKAGED PROPERLY WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTAND ING THIS MANUAL IF YOU ARE UNABLE TO UNDERSTA...

Страница 9: ...ING THE US DEPARTMENT OF TRANS PORTATION DOT AND UNITED NATIONS UN REGULATIONS REQUIRE THE REMOVAL OF THE BATTERY FROM THE DEVICE FOR ALL INTERNA TIONAL AIRLINE TRAVEL WHEN THE OXYGEN CONCENTRATOR IS...

Страница 10: ...IF UNABLE TO LEAVE THE ROOM YOU MUST WAIT 10 MINUTES AFTER YOU HAVE TURNED THE OXYGEN CONCENTRATOR OFF BEFORE SMOKING WARNING NO SMOKING OXYGEN IN USE SIGNS MUST BE PROMINENTLY DISPLAYED IN THE HOME O...

Страница 11: ...llow these instructions can result in the power supply not supplying power to the Oxygen Concentrator CAUTION When the automobile in which you are using the Oxygen Concentrator unit is turned off disc...

Страница 12: ...t Nominal Battery Recharge Time 1 8 to 5 0 hrs recharge time to achieve 80 capacity dependent upon the flow Alarms Alerts Loss of power Low Battery Low Therapeutic O2 Output O2 flow outside normal lim...

Страница 13: ...et filter at the top rear of the cabi net and allow exhaust air to freely leave the exhaust vent at the bottom left of the device Place the device such that the alarms can be heard Position the oxygen...

Страница 14: ...326 AC POWER SUPPLY WITH TWO PINS The Eclipse 5 includes a universal AC Power Supply for use at home or wherever standard AC power is available To connect to an AC power source be sure the AC Power Su...

Страница 15: ...le from the vehicle s DC power outlet WARNING DO NOT ALLOW EITHER THE AIR INTAKE OR THE AIR OUTLET VENTS TO BECOME BLOCKED THIS CAN CAUSE THE OXYGEN CONCEN TRATOR TO OVERHEAT AND IMPAIR PERFORMANCE WA...

Страница 16: ...RES OR WITH A FULLY CHARGED OR COMPLETELY DISCHARGED BATTERY CAN DEGRADE ITS OVERALL BATTERY LIFE DO NOT ATTEMPT TO OPEN THE BATTERY THERE ARE NO SERVICEABLE PARTS INSIDE THE BATTERY KEEP BATTERIES AW...

Страница 17: ...Note Operating the Oxygen Concentrator outside of its normal operating temperature range can affect performance and decrease battery run time and or increase battery charge time Refer to the Specific...

Страница 18: ...ot detected The device will continually check for an inspiratory effort every 15 seconds Once an inspiration is detected the device reverts to measured bolus delivery To exit Pulse Dose Mode and engag...

Страница 19: ...7 feet 2 1 m of tubing PN 5408 SEQ For any additional recommended accessories please see the Accessories Catalog PN ML LOX0010 available on www CAIREmedical com A firebreak is required for use with an...

Страница 20: ...he yellow light is on Battery symbol is flashing on LCD The Eclipse 5 power cartridge voltage may be low 1 Plug Eclipse 5 into AC power supply and recharge or replace power cartridge with fully charge...

Страница 21: ...battery CHARGER ON OR OFF ON 1 alarm beep repeat every 20 seconds 001 Ambient pressure fail AMB PRESS ON OR OFF ON 1 alarm beep repeat every 20 seconds 004 O2 85 After warm up O2 LOW OFF ON 1 alarm be...

Страница 22: ...sformer as well 3 Ensure that the power verification lights are on There will be a green light on the power supply box There will be a green light on the Eclipse 5 concentrator control panel in the sh...

Страница 23: ...be a green light on the Eclipse 5 concentrator control panel in the shape of a power cord 4 If power verification LEDs are not lit remove all connections of the power supply for 20 seconds and reconne...

Страница 24: ...r in warm tap water using a mild soap detergent solution 3 Rinse the filter thoroughly with clear tap water and squeeze out the excess water 4 Allow the filter to air dry 5 Reinsert the filter in the...

Страница 25: ...BASED PROD UCTS CONCENTRATED CHLORINE BASED PROD UCTS ETHYLENE CHLORIDE AND OIL BASED PRODUCTS PINE SOL LESTOIL THESE ARE NOT TO BE USED TO CLEAN THE PLASTIC HOUS ING ON OXYGEN CONCENTRATOR AS THEY CA...

Страница 26: ...ssions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The device is suitable for use in all establishments including domestic es...

Страница 27: ...mmended that the Eclipse 5 is powered from an uninterruptible power supply UPS Power frequency magnet ic field IEC 61000 4 8 30A m Power frequency magnetic fields should be at levels characteristic of...

Страница 28: ...28 ENG PN 21182453 C User Manual Eclipse 5 NOTES...

Страница 29: ...PN 2118245 C User Manual 29 ENG Eclipse 5 NOTES...

Страница 30: ...30 ENG PN 21182453 C User Manual Eclipse 5 NOTES...

Страница 31: ...2 3 3 4 5 5 6 7 8 Table is based on 20 Breaths Per Minute for Pulse Dose Mode only 7 1 2 2 3 3 4 5 5 6 6 8 1 2 3 3 4 5 6 6 7 8 9 1 2 3 4 5 6 7 8 8 9 Table is based on 15 Breaths Per Minute for Pulse...

Страница 32: ...2018 Chart Industries Chart Industries reserves the right to discontinue its products or change the prices materials equipment quality descriptions specifications and or processes to its products at a...

Отзывы: