6.10 GRACE
3
WALL MOUNTING (OPTIONAL)
The stove is suitable for wall mounting. The can be attached to a load-bearing wall in masonry (NOT plasterboard, wood, etc...)
suitable for the entire weight of the stove.
Fig. 54 - Wall mounting
LEGEND
Fig. 54
1
Stove
2
Minimum lateral distance = 300 mm
4
Minimum front distance = 1000 mm
5
Support distance = 40 mm
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides
to enable an eficient appliance cooling and a good distribution of heat in the room (see
Fig. 54
).
In some countries also masonring load-bearing walls are considered flammable.
If you want to fix the stove to a non-flammable material wall, you need to fix the support to the wall (optional cod. 5019009).
Call an expert to prepare the fumes outlet hole and the combustion air inlet hole.
EXAMPLE OF INSTALLATION OF THE STOVE AT 8 CM FROM THE GROUND:
• Drill the holes in the wall for fumes extraction (ref. 1) and the combustion air (ref. 2) as indicated in
Fig. 55
.
• Fix the support to the wall (ref. 3) using metal dowels (ref. 4) suitable for bearing the stove weight.
• Secure the clamping bracket (ref. 5) on the back of the stove. Use the screws already present on the back (see
Fig. 56
).
• Lift the stove and hook it to the support (see
Fig. 57
). At this stage, also connect fumes and air combustion tubes.
• Secure everything with the screw (ref. 6).
• Follow the procedure in reverse order to remove.
Fig. 55 - Step 1
Fig. 56 - Step 2