23
GRACE - SPIRIT 5 - ATRIUM 5 - SOLO - ROXY - TABLA - MADISON 5
• Press the "
menu
" button to confirm.
6.13 CONNECTION TO THE EXTERNAL THERMOSTAT
Fig. 61 - 3-key display
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the menu key for a few seconds (1).
• Repeatedly press the P2 key until
M8 - Technical settings
"
M8-SEt tEcHnic
" appears.
• Select by pressing the P3 key.
• Set the password with keys P1 or P2 (keeping the key pressed accelerates the setting).
• Confirm by pressing the P3 key.
• Press the P1 or P2 keys until
M8 - 2 General settings
"
M8-2 SEt GEnErAL
" appears.
• Confirm with P3.
• Scroll with the P3 key up to:
Pr46 Enable Remote
"
Pr46 rEMoto EnAbLEd
".
• Press the P1 or P2 key to modify the status.
• Confirm with the P3 key.
• Scroll to
MB Output
"
Mb EScAPE
" with key P1 or P2.
• Confirm with P3 key.
•
• Press P1 (temperature setting) and set
t-e
“
t-E
” value. The external thermostat is now enabled.
6.14 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• The depression detection point is located behind the pellet tank.
• Connect a digital pressure switch with a tube to detect the depression (see
Fig. 62
).
• Load the feed screw via appropriate function.
• Start the stove and set "Fire" at power 1 (the start of this stove lasts from 8 to 10 minutes to ensure minimum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.
Fig. 62 - Connecting the digital pressure switch