![Cadel GRACE 7 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/cadel/grace-7/grace-7_installer-manual_3510104024.webp)
GRACE - SPIRIT 5 - ATRIUM 5 - SOLO - ROXY - TABLA - MADISON 5
24
DATA
P1
P2
P3
P4
P5
Stove depression - temperature 5,2 kW 20 Pa - 160°C
22 Pa - 170°C
24 Pa - 190°C
29 Pa - 195°C
33 Pa - 210°C
Stove depression - temperature 7 kW
25/26 Pa - 190°C 29/30 Pa - 200°C 34/35 Pa - 220°C 40/41 Pa - 240°C 47/48 Pa - 250°
NB: for good combustion, the depression values must be b -5 Pa and the temperature values b - 10°C.
7
SPECIAL MAINTENANCE
7.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
7.2
FUME CONDUIT CLEANING
The exhaust system must be cleaned every 2/3 months.
Fig. 63 - Fume conduit cleaning
• Remove the inspection lid of the T-union (see
Fig. 63
).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
7.3
FUME PASSAGES CLEANING
Clean the fume passages every year.