![Cadel GRACE 7 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/cadel/grace-7/grace-7_installer-manual_3510104026.webp)
GRACE - SPIRIT 5 - ATRIUM 5 - SOLO - ROXY - TABLA - MADISON 5
26
Fig. 69 - Room fan cleaning
MODELS (GRACE3 - ROXY - TABLA)
• Remove the door and the front coating (see dedicated chapters).
• The room fan is fixed to the back of the stove, to remove it loosen the 4 screws behind the stove (see
Fig. 70
).
• Remove the fan and vacuum the ash and dust accumulated in the fan (see
Fig. 71
).
Fig. 70 - Remove the screws
Fig. 71 - Room fan cleaning
7.5
FUME PIPES ANNUAL CLEANING
Clean annually from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney
flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This
operation must be executed at least once a year.
7.6
GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.