FRAME - QUASIMODO - MODO Airtight
29
9
TECHNICAL DATAS
9.1
FUSE REPLACEMENT
For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
Fig. 72
).
Fig. 72 - Shutter with fuses to remove
10 FEATURES
DESCRIPTION
FRAME
3
7 kW
FRAME
3
9 kW
FRAME
3
UP 9 kW
WIDTH
70,3 cm
70,3 cm
70,3 cm
DEPTH
53 cm
53 cm
53 cm
HEIGHT
78 cm
78 cm
78 cm
WEIGHT
105 kg
105 kg
106 kg
INTRODUCED THERMAL POWER (Min/Max)
2,85 - 7,91 kW
2,85 - 10,51 kW
2,85 - 10,51 kW
NOMINAL THERMAL POWER (Min/Max)
2,7 - 7,2 kW
2,7 - 9,3 kW
2,7 - 9,3 kW
EFFICIENCY (Min/Max)
93,9 - 91 %
93,9 - 89 %
93,9 - 89 %
FLUE GAS TEMPERATURE (Min/Max)
76 - 147 °C
76 - 190°C
76 - 190°C
MAXIMUM FLUE GAS FLOW RATE (Min/Max)
2,8 - 4,8 g/s
2,8 - 5,7 g/s
2,8 - 5,7 g/s
CO EMISSIONS (13% O2) (Min/Max)
0,021 - 0,009 %
0,021 - 0,009 %
0,021 - 0,009 %
OGC EMISSIONS (13% O
2
) (Min/Max)
3,2 - 1,0 mg/Nm3
3,2 - 2,1 mg/Nm3
3,2 - 2,1 mg/Nm3
NOX EMISSIONS (13% O
2
) (Min/Max)
108 - 116 mg/Nm3
108 - 119 mg/Nm3
108 - 119 mg/Nm3
Average CO CONTENT at 13% O
2
(Min/Max)
265 - 114 mg/Nm3
265 - 107 mg/Nm3
265 - 107 mg/Nm3
Average DUST CONTENT at 13% O
2
(Min/Max)
18 - 18 mg/Nm3
18 - 19 mg/Nm3
18 - 19 mg/Nm3
FLUE NEGATIVE PRESSURE (Max)
11,4 Pa
11,8 Pa
11,8 Pa
ON SHARED FLUE
NO
NO
NO
FLUE GAS EXHAUST DIAMETER
Ø80 mm
Ø80 mm
Ø80 mm
FUEL
Pellet Ø6-7 mm
Pellet Ø6-7 mm
Pellet Ø6-7 mm
PELLET HEATING CAPACITY
5 kWh/kg
5 kWh/kg
5 kWh/kg
PELLET HUMIDITY
≤ 10%
≤ 10%
≤ 10%
HEATABLE VOLUME 18/20°C Coeff. 0.045 kW (Min/Max)
65 - 173 m3
65 - 223 m3
65 - 223 m3
HOURLY CONSUMPTION (Min/Max)
0,59 - 1,64 kg/h
0,59 - 2,18 kg/h
0,59 - 2,18 kg/h
HOPPER CAPACITY
15 kg
15 kg
15 kg
RANGE (Min/Max)
25 - 9,1 h
25 - 6,9 h
25 - 6,9 h
POWER SUPPLY
230 V - 50 Hz
230 V - 50 Hz
230 V - 50 Hz
ABSORBED POWER (Max)
346 W
346 W
346 W
STARTER RESISTANCE ABSORBED POWER
300 W
300 W
300 W
MINIMUM EXTERNAL AIR VENT (final cross-section)
80 cm2
80 cm2
80 cm2
SEALED CHAMBER STOVE
YES
YES
YES
EXTERNAL AIR VENT FOR SEALED CHAMBER
60 mm
60 mm
60 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/bottom)
200 / 200 / 0 mm
200 / 200 / 0 mm
200 / 200 / 0 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front)
750 / 1000 mm
750 / 1000 mm
750 / 1000 mm
Содержание FRAME3