Revision 1 2017
CDC seven
27
CDC I/O 6448 – rear panel
BOOT
SWITCH
Port A
Port B
Tx
Rx
Rx
Tx
+
-
+
+
18V
FPGA stat0
18V
FPGA stat1
48V
PIC stat0
12V
Spare
Port A Tx
Port B Tx
Port A Rx
Port B Rx
CDC I/O 6448
MAINS INPUT
240V
~ 50/60 Hz
AC ONLY 100 -
REPLACE ONLY WITH SPECIFIED
TYPE AND RATED FUSE
TO PREVENT ELECTRIC SHOCK
UNPLUG UNIT FROM AC MAINS SUPPLY
BEFORE REMOVING PANEL
DO NOT OBSTRUCT AIR VENTS
AUX PWR
SERIAL
NUMBER
CONNECT ONLY TO PSU
SUPPLIED AND SPECIFIED
BY CADAC.
REFER TO MANUAL FOR DETAILS.
0
9 8
2
1
Designed and Engineered in England
Assembled in China
FUSE: T3.15AL 250V
110W
~
1
AUX PWR
Port B Tx
Port B Rx
Port A Tx
Port A Rx
A
Port A
Port B
Tx
Rx
Rx
Tx
BOOT
SWITCH
0
9 8
2
1
+
-
+
+
18V
18V
48V
12V
FPGA stat0
A
FPGA stat1
A
PIC stat0
Spare
2
3
3
4
11
12
10
5
6
9
1. MAINS INPUT – IEC receptacle with an integral fuse and rocker switch.
2. AUX POWER – 12-pin connector for external backup CDC PSU 4800.
3. Cadac MegaCOMMS data – 4 x BNC connectors carrying all audio
and control data between the control surface (or MC Router) and the
stagebox. See “Connecting the hardware” on page 28 for full details.
4. Port status LEDs – one yellow and three green LEDs per port. In normal
operation one or more green LEDs per port should be illuminated; the
number will vary, and depends on the bandwidth in use. The yellow LED
flashes when no MegaCOMMS signal is present at the port. Unconnected
ports will have no indication on the corresponding LED bank.
5. Power rail status LEDs – four green LEDs, one per internal voltage rail
(18V, -18V, +48V, +12V). All must be lit for correct operation.
6. FPGAstat0 – red LED; used in factory testing only, should be unlit in
normal operation.
7. FPGAstat1 – red LED, illuminates to indicate loss of lock to the incoming
MegaCOMMS signal. Should be unlit in normal operation.
8. PICstat0 – red LED, flashes during power-on and firmware updates only.
If on otherwise, a boot failure is indicated.
9. Spare – red LED; not currently implemented
10. USB – type ‘A’ USB 2.0 port, used for firmware updates. NOTE: this port
is ONLY intended for the connection of memory sticks. Do not connect
any other type of USB device to this port.
11. BOOT SWITCH – for factory use only. Do not press.
12. Hex switch – set according to how the stagebox is being connected:
• Set to ‘1’ when connecting the stagebox to a CDC MC Router.
• Set to ‘2’ when connecting the stagebox to a CDC seven surface,
and it is to be used as RACK 1.
• Set to ‘3’ when connecting the stagebox to a CDC seven surface,
and it is to be used as RACK 2.
All other hex switch positions are unused.