background image

2

WIRED REMOTE CONTROLLER
(KSACN0301AAA)

Enter/cancel

Enter/Cancel

Fan

Mode

Function

Timer

On/Off

SHIELD MEMORY MASTER SAVE

BLOW

QUIET

CO

2

AUTO TURBO

SET
HOUR

F

E-HEATER

A
U
T
O

Fig. 2

 - 

Wired Remote Controller

WIRED REMOTE CONTROLLER LCD DISPLAY

SHIELD MEMORY MASTER SAVE

BLOW

QUIET

CO

2

AUTOT URBO

SET
HOUR

F

E-HEATER

A
U
T
O

1

3

4 5 6

7 8 9 10

12

11

13 14 15

16

17 18 19

2

Fig. 3

 - 

LCD Display

LCD DISPLAY ICON DESCRIPTIONS

Table 1—Icon Descriptions

n

o

i

t

p

i

r

c

s

e

D

s

l

o

b

m

y

S

.

o

N

1

Swing function

2

Sleep function (Only sleep 1)

3

Indoor unit running modes (COOLING, DRY, FAN and HEATING)

4

Defrosting function for the outdoor unit

5

Gate-control function

 (

Not Available on these units

)

6

Lock function

7

High, middle, low or auto fan speed of the indoor unit

8

Shield functions (buttons, temperature, On/Off or Mode is shielded 
by the remote monitor)

9

Turbo function

10

Memory function (the indoor unit resumes the original setting
condition following a power failure)

11

Master wired remote controller 

(

Not Available on these units)

 

12

It blinks under the unit’s On state without pressing any button

13

Energy-saving function (Not Available on these units)

14

Ambient/preset temperature value

15

Electric auxiliary heating function (Not Available on these units)

16

Blow function

17

Timing value

18

Quiet function (two types: quiet and auto quiet)
(Not Available on these units)

19

SET

It appears under the debugging mode

Содержание KSACN0301AAA

Страница 1: ...ntial for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in sev...

Страница 2: ...unction for the outdoor unit 5 Gate control function Not Available on these units 6 Lock function 7 High middle low or auto fan speed of the indoor unit 8 Shield functions buttons temperature On Off o...

Страница 3: ...case no other buttons will respond if pressed Press them again together for 5 secs to exit the mode 4 6 If there is a preference for F rather than C default under OFF state press 5 7 Function Timer Un...

Страница 4: ...Heating Fig 7 MODE Setting TEMPERATURE SETTING Press or to increase or decrease the temperature If these buttons are pressed continuously the temperature either increases or decreases by 1 8_F 1_C ev...

Страница 5: ...ses or decreases the set time by 0 5 hour If either of the arrows are pressed continuously the set time will increaseor decrease by 0 5 hour ever 0 5 seconds SWING MODE S SWING ON Press FUNCTIONunder...

Страница 6: ...to run at this temperature In the HEATING mode the temperature decreases by 1 8_F 1_C after the unit runs under SLEEP 1 for one hour and 1 8_F 1_C after another hour Afterwards the unit runs at this t...

Страница 7: ...r a power failure and the subsequent power recovery S Memory Recovery If this function has been set for the wired remote controller the controller after power failure resumes its original running stat...

Страница 8: ...nstallation instructions of each indoor unit for proper installation Connect the 4 core wire shipped with the unit to CN9 on the indoor board and CN1 on the wired controller board INSTALLATION AND DIS...

Страница 9: ...anel and the wired remote controller plate tightly with the screws ST2 9X6 1 6 8 9 10 7 3 4 5 2 Fig 17 Installation Steps Please pay special attention to the following directions during the connection...

Страница 10: ...ion P5 7 H g n i z i n o r h c n y s e d r o s s e r p m o C c H n o i t c e t o r p C F P IPM Temperature Protection P8 IPM Current protection H5 9 L n o i t c e t o r p r e w o p r e v O Compressor...

Отзывы: