background image

KSACN0301AAA

Owner's Manual

Wired Controller for

Ducted and Cassette Ductless Systems

NOTE: Read the instruction manual before starting the installation.

SAFETY CONSIDERATIONS

Installing, starting up, and servicing air−conditioning equipment
can be hazardous due to system pressures, electrical components,
and equipment location (roofs, elevated structures, etc.).

Only trained, qualified installers and service mechanics should
install, start−up, and service this equipment.

Untrained personnel can perform basic maintenance functions such
as cleaning coils. All other operations should be performed by
trained service personnel.

When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.

Follow all safety codes. Wear safety glasses and work gloves. Keep
quenching cloth and fire extinguisher nearby when brazing. Use
care in handling, rigging, and setting bulky equipment.

Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit. Consult
local building codes and National Electrical Code (NEC) for
special requirements. Recognize safety information.

This is the safety−alert symbol 

!

 !

. When you see this symbol on

the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand these signal words: DANGER,
WARNING, and CAUTION. These words are used with the
safety−alert symbol. DANGER identifies the most serious hazards
which  will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which may result in
minor personal injury or product and property damage. NOTE is
used to highlight suggestions which will result in enhanced
installation, reliability, or operation.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal
injury or death.

Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF
position. There may be more than 1 disconnect switch.
Lock out and tag switch with a suitable warning label.

!

WARNING

ELECTRICAL DAMAGE HAZARD

Failure to follow this caution may result in equipment
damage or improper operation.

Do not install the wired controller in an area subjected
to excessive steam, oil or sulfide gas. Doing so may
cause the controller to to deform and/or fail.

Enter/cancel

Enter/Cancel

Fan

Mode

Function

Timer

On/Off

SHIELD MEMORY MASTER SAVE

BLOW

QUIET

CO

2

AUTO TURBO

SET
HOUR

F

E-HEATER

A
U
T
O

Fig. 1

 - 

Wired Controller

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

WIRED REMOTE CONTROLLER (KSACN0301AAA)

2

. . . . .

LCD DISPLAY ICON DESCRIPTIONS

2

. . . . . . . . . . . . . . . . . .

WIRED REMOTE CONTROLLER BUTTONS

3

. . . . . . . . . . . .

OPERATION INSTRUCTIONS

4

. . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION AND DISASSEMBLY

8

. . . . . . . . . . . . . . . . .

Содержание KSACN0301AAA

Страница 1: ...ntial for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in sev...

Страница 2: ...unction for the outdoor unit 5 Gate control function Not Available on these units 6 Lock function 7 High middle low or auto fan speed of the indoor unit 8 Shield functions buttons temperature On Off o...

Страница 3: ...case no other buttons will respond if pressed Press them again together for 5 secs to exit the mode 4 6 If there is a preference for F rather than C default under OFF state press 5 7 Function Timer Un...

Страница 4: ...Heating Fig 7 MODE Setting TEMPERATURE SETTING Press or to increase or decrease the temperature If these buttons are pressed continuously the temperature either increases or decreases by 1 8_F 1_C ev...

Страница 5: ...ses or decreases the set time by 0 5 hour If either of the arrows are pressed continuously the set time will increaseor decrease by 0 5 hour ever 0 5 seconds SWING MODE S SWING ON Press FUNCTIONunder...

Страница 6: ...to run at this temperature In the HEATING mode the temperature decreases by 1 8_F 1_C after the unit runs under SLEEP 1 for one hour and 1 8_F 1_C after another hour Afterwards the unit runs at this t...

Страница 7: ...r a power failure and the subsequent power recovery S Memory Recovery If this function has been set for the wired remote controller the controller after power failure resumes its original running stat...

Страница 8: ...nstallation instructions of each indoor unit for proper installation Connect the 4 core wire shipped with the unit to CN9 on the indoor board and CN1 on the wired controller board INSTALLATION AND DIS...

Страница 9: ...anel and the wired remote controller plate tightly with the screws ST2 9X6 1 6 8 9 10 7 3 4 5 2 Fig 17 Installation Steps Please pay special attention to the following directions during the connection...

Страница 10: ...ion P5 7 H g n i z i n o r h c n y s e d r o s s e r p m o C c H n o i t c e t o r p C F P IPM Temperature Protection P8 IPM Current protection H5 9 L n o i t c e t o r p r e w o p r e v O Compressor...

Отзывы: