11
Install the generator as close as possible to the fuel
•
supply, to reduce the length of piping.
Install the generator as close as possible to the
•
transfer switch. REMEMBER THAT LAWS OR
CODES MAY REGULATE THE DISTANCE AND
LOCATION.
The genset must be installed on a level surface.
•
The base frame must be level within two (2) inches
all around.
The generator is typically placed on pea gravel or
•
crushed stone. Check local codes if a concrete slab
is required. If a concrete base slab is required, all
federal, state and local codes should be followed.
Special attention should be given to the concrete
base slab which should exceed the length and
width of the generator by a minimum of six (6)
inches (0.152 meters) on all sides.
The engine exhaust fumes contain carbon mon-
oxide, which can be DEADLY. This dangerous
gas, if breathed in sufficient concentrations,
can cause unconsciousness or even death. This
exhaust system must be installed properly, in
strict compliance with applicable codes and stan-
dards. Following installation, do nothing that
might render the system unsafe or in noncompli-
ance with such codes and standards.
• Operate the generator outdoors ONLY.
• Keep exhaust gases from entering a confined area
through windows, doors, ventilation or other
openings (Figure 1.9).
1.11.2 TRANSFER SWITCH (
if included)
1.11.2.1 8, 10, 12, 14, 16, 17 and 20kW Units
(if equipped)
The transfer switch that may have shipped inside
the carton with the
8, 10, 12, 14, 16 or 17kW
gen-
erator is enclosed in a
NEMA 1 (indoor rated only)
enclosure. The transfer switch that may have shipped
with the
20kW
generator is enclosed in a
NEMA 3R
(indoor/outdoor rated)
enclosure.
Install the transfer switch indoors on a firm, sturdy
•
supporting structure.
To prevent switch distortion, level the switch if
•
necessary. This can be done by placing washers
between the switch enclosure and mounting sur-
face.
Never install the switch where water or any corro-
•
sive substance might drip onto the enclosure.
Protect the switch at all times against excessive
•
moisture, dust, dirt, lint, construction grit and
corrosive vapors.
If the AUTO/OFF/MANUAL switch is not set to its
OFF position, the generator can crank and start
as soon as the battery cables are connected. If
the utility power supply is not turned off, spark-
ing can occur at the battery posts and cause an
explosion.
1.12 BATTERY REQUIREMENTS
See the Specifications section for correct battery size
and rating.
1.13 BATTERY INSTALLATION
Fill the battery with the proper electrolyte fluid if
necessary and have the battery fully charged before
installing it.
Before installing and connecting the battery, complete
the following steps:
1. Set the generator's AUTO/OFF/MANUAL switch to
OFF.
2. Turn off utility power supply to the transfer
switch.
3. Remove the 7.5A fuse from the generator control
panel.
Battery cables were factory connected at the genera-
tor (Figure 1.10). Connect cables to battery posts as
follows:
4. Connect the red battery cable (from starter con-
tactor) to the battery post indicated by a positive,
POS or (+).
5. Connect the black battery cable (from frame
ground) to the battery post indicated by a nega-
tive, NEG or (—).
Figure 1.10 – Battery Cable Connections
Section 1 — General Information
Air-cooled Generators
Содержание 8kW
Страница 1: ...Study Guide S e r v i c e T r a i n i n g Air Cooled Training...
Страница 2: ......
Страница 36: ...32 32 Section 7 Notes Air cooled Generators...
Страница 37: ...33 Section 8 Installation Diagrams Air cooled Generators Circuit Breakers Drawing No 0G8573 A...
Страница 38: ...34 Section 8 Installation Diagrams Air cooled Generators Generator Drawing No 0G8280 D...
Страница 39: ...35 Section 8 Installation Diagrams Air cooled Generators Generator Drawing No 0G8280 D...
Страница 42: ...Part No 0G8334 Revision D 09 16 08 Printed in U S A Catalog No OMASPCA S 01...
Страница 43: ...TECHNICAL MANUAL This manual should remain with the unit RTSS Load Shed Automatic Transfer Switch...
Страница 54: ...10 Section 4 Installation Diagrams RTSS Type Transfer Switch Load Shed Interconnection Drawing No 0G8774 B...
Страница 55: ...11 Section 4 Installation Diagrams RTSS Type Transfer Switch 200 Amp Load Shed Enclosure Drawing No 0G8775 B...
Страница 56: ...12 Section 5 Electrical Data RTSS Type Transfer Switch Electrical Schematic Drawing No 0G7816 A...
Страница 57: ...13 Section 5 Electrical Data RTSS Type Transfer Switch Electrical Schematic Drawing No 0G7816 A...
Страница 58: ...14 Section 5 Electrical Data RTSS Type Transfer Switch Wiring Diagram Drawing No 0G7817 B...
Страница 59: ...15 Section 5 Electrical Data RTSS Type Transfer Switch Wiring Diagram Drawing No 0G7817 B...
Страница 64: ...20 Section 7 Notes...
Страница 65: ...21 Section 7 Notes...
Страница 66: ...Part No 0G8637 Revision D 08 27 08 Catalog No KGALT 1SI Printed in U S A...
Страница 68: ......
Страница 76: ...8 Residential Transfer Switch Installation Guide Installation Drawing 0H0258 A...
Страница 77: ...9 Residential Transfer Switch Installation Guide Installation Drawing 0H0258 A...
Страница 78: ...Residential Transfer Switch Installation Guide Installation Drawing 0G8573 A 10 10...
Страница 79: ...11 Residential Transfer Switch Installation Guide Electrical Schematic Drawing 0G7959 A...
Страница 80: ...12 Residential Transfer Switch Installation Guide Wiring Diagram Drawing 0G7958 A...
Страница 81: ...13 Residential Transfer Switch Installation Guide Wiring Diagram Drawing 0G7958 A...
Страница 82: ...14 Residential Transfer Switch Installation Guide Load Center Exploded View Drawing 0G8786 C...
Страница 84: ...16 Residential Transfer Switch Installation Guide Notes...
Страница 85: ...17 Residential Transfer Switch Installation Guide Notes...
Страница 86: ...Part No 0G8571 Revision D 07 31 08 Catalog No KGATX100 1SI Printed in U S A...
Страница 91: ...5 REFERENCE Items supplied in the EZ Transfer operator kit...
Страница 92: ...6...
Страница 93: ...7...
Страница 95: ...Air cooled Generator Battery Charger Installation Guidelines...
Страница 105: ...9 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines RTSS Diagram Drawing No 0G8774 B...
Страница 106: ...10 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines RTSN Diagram Option 1 Drawing No 0G8832 A...
Страница 107: ...11 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines RTSN Diagram Option 2 Drawing No 0G8832 A...
Страница 108: ...12 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines RTSE Diagram Option 1 Drawing No 0G8829 A...
Страница 109: ...13 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines RTSE Diagram Option 2 Drawing No 0G8829 A...
Страница 110: ...14 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines GenReady Diagram Drawing No 0G4744 D...
Страница 111: ...15 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines GenReady Diagram Drawing No 0G4744 D...
Страница 112: ...16 Section 5 Interconnection Diagrams Battery Charger Installation Guidelines GenReady Diagram Drawing No 0G4744 D...
Страница 113: ...17 Section 6 Notes Battery Charger Installation Guidelines...
Страница 114: ...Part No 0G7956 Revision B 11 14 08 Printed in U S A...
Страница 115: ......