INSTALLING THE CONCENTRATOR MODULE
3-8
3.5
FINISHING THE INSTALLATION
With power on at the MMAC and the attached stations, check that
the red Error LED on the concentrator module is not lit and no error
indications exist at the attached stations. The green Link Attached
LEDs on the MIM should be illuminated for each station that is
inserted into the ring. The yellow 16MB LED should only be on if
the concentrator module is set for 16 Mbit/s ring speed.
If these conditions do not exist, proceed to Chapter 4, Testing and
Troubleshooting
.
The concentrator is now ready for operation. Before placing the
network into service, test the installation thoroughly to be sure that
all stations are able to be addressed and that the data is being
relayed without error. Verify that the networking software is
configured properly to match the installed network.