REQUIREMENTS/SPECIFICATIONS
2-12
LNK
- Link Status (Green - 12 or 24), when lit, indicates that the
associated station is providing phantom current. If the port has
been made a Ring-Out port by the MMAC management module,
the LNK LED stays lit even with no connection.
MGMT
- Management (Green) when lit, indicates that the
concentrator module is in Management Mode. Settings are stored
by the management module in slot 0.
2.3.5
General Specifications
SAFETY
Warning:
It is the responsibility of the person who sells the system to
which the TRMIM-22A/TRMIM-24A/TRMIM-42A/TRMIM-44A will
be a part to ensure that the total system meets allowed limits of conducted
and radiated emissions.
This equipment is designed in accordance with UL478, UL910, NEC
725-2(b), CSA, IEC, TUV, VDE Class A, and meets FCC part 15,
Class A limits.
SERVICE
TRMIM-22A/42A
TRMIM-24A/44A
MTBF (MHBK-217E)
48,000 hrs.
50,000 hrs.
MTTR
<0.5 hr.
<0.5 hr.
PHYSICAL
Dimensions
13.4D x 11.5H x 2.0W inches
(includes front panel)
(34.0D x 29.2H x 5.1W centimeters)
Weight
2 lbs. 2 oz.
(963.9 grams)