5-2 SmartCell 6A000 User Guide
Troubleshooting LAN Emulation
Troubleshooting
5.
If working through these questions does not solve the problem, contact Cabletron Systems Customer
Service. (See Appendix C, “Technical Support.”)
5.2
TROUBLESHOOTING LAN EMULATION
You have configured an Emulated LAN and your network applications are not working. Use these questions and tests
to help determine the cause of the problem.
1.
Check for connectivity. Try pinging between end nodes. Ping from the SmartCell 6A000 (using
start ping
) to its end nodes. If you cannot ping, check physical connectivity (disconnected cable
and so on).
2.
Check IP routes and addresses.
•
Use
show route
command to check the SmartCell 6A000 route table.
-
Are the destination addresses correct for the specified gateways?
-
Are there any routing loops?
-
Are one or more of the destination addresses mapped to the wrong subnet?
•
Use
show client
to check the SmartCell 6A000 local ELAN client.
-
Does the client have the correct IP address?
-
Is the subnet correct?
-
Is the ATM address correct?
-
Is the server type correct?
•
Check end nodes configurations.
-
Are end nodes configured correctly?
3.
If the ELAN spans multiple switches, check the following:
-
Is the LECS address correct on all switches?
-
Can all switches reach the switch providing LECS support?
-
If using the Well Known LECS Address, are all switches correctly mapped?
4.
Check the LECS database.
•
Use
show lecselan
to check the names and numbers of ELANs.
-
Are ELAN names correct?
-
Is the ATM address of the LES correct?
5.
Check whether BUS is connected.
•
Use
show busclient
to check whether devices are registered with the BUS. If clients are registered,
check end node configuration. If not registered, check multi-point signaling.
•
Use
set leselan
to turn off multi-point signaling on a per-ELAN basis.
-
Do devices begin to register with the LES and BUS once multi-point signaling is turned off?
•
Check IISP routes to the switch containing the LES and BUS.
-
Are all IISP routes correct?
-
Does a new IISP route need to be added so devices can reach the LES and BUS?
Содержание SmartCell 6A000
Страница 12: ...xii SmartCell 6A000 User Guide TABLE OF CONTENTS...
Страница 14: ...xiv SmartCell 6A000 User Guide List of Figures...
Страница 16: ...xvi SmartCell 6A000 User Guide List of Tables...
Страница 18: ...1 2 SmartCell 6A000 User Guide Introduction...
Страница 34: ...2 16 SmartCell 6A000 User Guide SmartSwitch ATM Administrator Switch Installation and Setup...
Страница 42: ...3 8 SmartCell 6A000 User Guide F amV m h d F 2 6 3 F 1 m 2...
Страница 80: ...5 6 SmartCell 6A000 User Guide Troubleshooting Congestion Troubleshooting...
Страница 86: ...A 6 SmartCell 6A000 User Guide Technical Specifications Specifications...
Страница 94: ...Appendix B 8 SmartCell 6A000 User Guide Managing the SmartCell 6A000 Agent Support...
Страница 108: ...Appendix D 12 SmartCell 6A000 User Guide Acronyms...