SmartCell 6A000 User Guide 4-3
Switch Administration
ATM Routing
4.
Enter the
add ATMRoute
command to create a static route to the IISP device:
SmartCell ZX # add atmroute
PortNumber(A1) : b2
AtmAddress() : 52:00:00:00:00:00:00:00:00:00:14:51:80
PrefixLength(104) :
Index(0) :
Type(Internal) :exterior
Scope(0) :
MetricsTag(0) :
SmartCell ZX #
Note
The
add ATMRoute
command allows you to specify a set of metrics to be used with
the route. For more on metrics and metric tags, see Section 4.2.3 “Route Metrics.”
5.
Enter the
show ATMRoute
command to determine whether the route was created:
SmartCell ZX # show atmroute
AddressNumber(ALL) :
No. Port Route Address Type Protocol
================================================================================
1 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80 I MGMT
2 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81 I MGMT
3 -- 39:00:00:00:00:00:00:00:00:00:14:59:00 I PNNI
4 -- 39:00:00:00:00:00:00:00:00:00:28:e9:80 I PNNI
5 -- 39:00:00:00:00:00:00:00:00:00:28:f5:00 I PNNI
6 B4 47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT
7 B2 52:00:00:00:00:00:00:00:00:00:14:51:80 I MGMT
SmartCell ZX #
The route to the IISP device appears on the last line (Route No. 7).
6.
Create a route on the IISP device that refers to the net prefix
(
39:00:00:00:00:00:00:00:00:00:14:41:80
) of port
b2
on the SmartCell 6A000.
Note
For IISP routes to work with certain devices, ILMI may also need to be disabled
on the SmartCell 6A000. Use the
set PortConfig
command to disable ILMI on
the SmartCell 6A000 on a per-port basis.
IISP Routing Considerations
When creating routes between the SmartCell 6A000 (running PNNI) and IISP devices, the criteria that characterize
IISP connectivity still apply. To reach a SmartCell 6A000 within the PNNI domain, the IISP device must have a
configured route that points directly to a port on the target SmartCell 6A000. Conversely, there must be a SmartCell
6A000 that has a direct physical link (and a route over that link) to the IISP device. The following two examples
illustrate this point.
In Figure 4-1 Switch A is an IISP device connected to the PNNI domain through Switch B. Switch A contains an LEC,
which is a member of an ELAN whose LECS is on Switch C (within the PNNI domain). If the LEC on Switch A is to
make contact with the LECS on Switch C, Switch A must contain an IISP route (denoted by the dotted line) directly
to switch C. Furthermore, Switch B must contain a route to switch A over the physical link that connects the two
switches.
Содержание SmartCell 6A000
Страница 12: ...xii SmartCell 6A000 User Guide TABLE OF CONTENTS...
Страница 14: ...xiv SmartCell 6A000 User Guide List of Figures...
Страница 16: ...xvi SmartCell 6A000 User Guide List of Tables...
Страница 18: ...1 2 SmartCell 6A000 User Guide Introduction...
Страница 34: ...2 16 SmartCell 6A000 User Guide SmartSwitch ATM Administrator Switch Installation and Setup...
Страница 42: ...3 8 SmartCell 6A000 User Guide F amV m h d F 2 6 3 F 1 m 2...
Страница 80: ...5 6 SmartCell 6A000 User Guide Troubleshooting Congestion Troubleshooting...
Страница 86: ...A 6 SmartCell 6A000 User Guide Technical Specifications Specifications...
Страница 94: ...Appendix B 8 SmartCell 6A000 User Guide Managing the SmartCell 6A000 Agent Support...
Страница 108: ...Appendix D 12 SmartCell 6A000 User Guide Acronyms...