B Operations
A On-Line Node Operations
(Chapter 18)
A
Remote Control
– allows control of a remote Cabletron frame relay access
device (FRX4000, FRX6000, SmartSwitch 1800, or FRM).
B
Remote File Transfer
– transfers files between nodes.
C
Remote Software Update
– updates a remote node to a new release of
FRX4000/6000 software.
D
Local File Backup
– copies an FRX4000 file to a PC (running Procomm
Plus®) connected to the FRX4000's Console port.
E
Set ZMODEM Path
– configures a path that will be used by
Local File Restore
(see next entry) for copying files to an FRX4000.
F
Local File Restore
– copies a file to the FRX4000 from the PC running
Procomm Plus) connected to the Console port.
G Copy Backup Directory to ZMODEM PC
– copies an entire database (that was
backed up using On-Line Database Operations) to a PC (running Procomm
Plus) connected to the FRX4000's Console port.
H Copy Backup Directory from ZMODEM PC
– copies the database transferred
in item G above back to the FRX4000.
B On-Line Port Operations
(Chapter 18)
A
Disable a Port
– Takes any physical or logical serial port in the node off line.
B
Disable a Range of Ports
– Takes a specified group of same-type ports off
line.
C
Enable a Port
– Brings any physical or logical serial port in the node on line.
D
Enable a Range of Ports
– Brings a specified group of same-type ports on
line.
E
Quiesce a Port
– Causes any physical or logical serial port in the node to be
taken off line when there are no active connections.
F
Quiesce a Range of Ports
– Quiesces a specified group of same-type ports.
G
Unquiesce a Port
– Cancels the
Quiesce a Port
command (only if there are
still active connections on the port).
H
Unquiesce a Range of Ports
– Unquiesces a specified group of same-type
ports.
C On-Line Database Operations
– (Chapter 18) backs up database and/or system
files locally or remotely.
A
Back up the Current Database to a Remote FRX6000
B
Restore the Backed-Up Database to a Remote FRX6000
C
Restore the Backed-Up Database to a Remote FRX4000
D
Back up the Current Database to a Local Directory
E
Restore the Database from a Local Directory
F
Back Up the Current System Files to a Local Directory
(FRX6000 only)
G
Restore the System Files from a Local Directory
(FRX6000 only)
D
Test X.25 Address Translation Templates
– (Chapter 8) Tests templates to
assure they were correctly created.
E
Re-Load Initialization to Async Console
– (Chapter 18) Sends default terminal
settings to an Auxiliary Console on the node's Console port (FRX4000) or
COM1 port (FRX6000).
F
IP Ping Connectivity Test
– (Chapter 18) Uses the Ping function to determine
whether an IP host is reachable.
Содержание Netlink FRX4000
Страница 2: ......
Страница 16: ...xiv FRX4000 FRX6000 4 0 User Guide Rev 01 ...
Страница 17: ...Section I Getting Started ...
Страница 18: ......
Страница 24: ......
Страница 37: ...Section II Configuration ...
Страница 38: ......
Страница 52: ......
Страница 78: ......
Страница 106: ...7 24 FRX4000 FRX6000 4 0 User Guide Rev 01 ...
Страница 142: ...8 36 FRX4000 FRX6000 4 0 User Guide Rev 01 ...
Страница 186: ......
Страница 216: ......
Страница 266: ......
Страница 273: ...Section III Operation ...
Страница 274: ......
Страница 296: ......
Страница 324: ......
Страница 376: ......
Страница 377: ...Section IV Appendices ...
Страница 378: ......
Страница 384: ......
Страница 390: ......
Страница 396: ......
Страница 400: ......
Страница 405: ...Menu Structure E 5 ...
Страница 406: ...E 6 FRX4000 FRX6000 4 0 User Guide Rev 01 ...
Страница 425: ......
Страница 426: ......