A-5
EPIM-C
EPIM-C
The EPIM-C supports thin-net coaxial cabling and is equipped with an internal
Cabletron Systems TMS-3™ Transceiver. You can use the TERM switch on the
front of the EPIM-C to set the internal 50-ohm terminator. This eliminates the
need to connect the port to a tee-connector and terminator. Figure A-5 shows the
setting for the terminator switch.
Figure A-5. EPIM-C
Connector Type
This connector type is a BNC receptacle, with gold center contact, for use with
BNC type tee-connectors and RG-58 thin-net cable.
Grounding
For safety reasons, only one end of a thin-net segment should be connected to
earth ground. Connection to earth ground at more than one point on the segment
may cause dangerous ground currents.
The BNC port of the Coaxial Interface Modules is not connected to earth ground.
The transmitter power levels given above are Peak Power Levels after optical
overshoot. You must use a Peak Power Meter to correctly compare the values
given above to those measured on any particular port. If you are measuring
power levels with an Average Power Meter, add 3 dBm to the average power
measurement to correctly compare the average power values measured to the
values listed above (i.e., -33.5 dBm a 3 dB = -30.5 dBm peak).
NOTE
EPIM-C
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)
TERM