9C300-1 Environmental Module Operation
3-16
Figure 3-16. The Power Screen
Select <EXIT> to return to the System Screen.
The Power Supply Specific Screen
Select a power supply number from line 4 of the Power Screen, Figure 3-16, to
learn about a specific power supply in the SmartSwitch 9000 chassis. There is an
LCD screen available for each installed power supply, Figure 3-17.
•
Line 1 identifies the power supply selected and its serial number.
•
Line 2 identifies the power supply’s hardware revision, firmware revision of
the diagnostic controller and power loading factor as a percentage of its
capacity.
•
Line 3 provides the input and output voltages of the power supply.
Figure 3-17. The Power Supply Specific Screen
Select <EXIT> to return to the Power Screen.
STATUS 1 ON 2 ON
<1>
SUPPLIES INSTALLED 2 PWR REDUNDANCY
<EXIT>
<2>
HW REV xxx FW REV x.xx.xx LOAD xxx%
<EXIT>
PWR SUPPLY 1 SN xxxxxxxxxxxx
PWR IN 110V PWR OUT 57.1V 5.1V 3.3V