21

EN

htr

Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre. 
The opening of the STOP input stops the motor. All the safety inputs are deactivated, except for 
the Limit switch inputs /SW01/SW02/SWC1/SWC2).
Off: Automatic/semiautomatic function

(OFF)

1mot

The operating mode with 1 or 2 motors is selected:
On: The motor operation is synchronised. This function must be used in the following cases:
- for each single motor, connect it to M1: Terminals 1/2.
- for two synchronised motors (e.g. balancing doors), connect one motor to M1: terminals 1/2 
and the other to M2: terminals 3/4. Adjust the parameters related to motor 1, the M2 limit switch 
inputs are deactivated. TDMO and TDMC must be 0.
Off: For two non-synchronised motors, e.g. overlapping gate leaves, adjust TDMO and TDMC 
on the desired values.

(OFF)

mloc

Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Power is cut off to the electric lock output before each opening and closing operation.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the parameter TLOC.

(OFF)

BB

Activates or deactivates the push in closing function. Only with logic SLD:ON
On: The last second of the manoeuvre in closing phase is carried out at normal speed (disabling 
slowing) to favour a better hook of the electric lock.
Off: Function disabled.

(OFF)

TST1

Enables or disables checking of photocells on PHOT input, active both in closing and in opening.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See Fig.3 
- “PHOTO TEST”.
Off: Checking of photocells disabled at each manoeuvre. 

(OFF)

TST2

Enables or disables checking of photocells on PHOT inputs, active only in closing. 
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See Fig.3 
- “PHOTO TEST”.
Off: Checking of photocells disabled at each manoeuvre. 

(OFF)

TSTm

Enables or disables motors check.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. 
Off: Check disabled. 

(OFF)

rem

(Enables or disables remote radiotransmitters learning, as indicated in the paragraph “Remote 
transmitters learning”. 
On: Remote learning enabled.
Off: Remote learning not enabled.

(OFF)

CAUTION:

Any change to one of these parameters/logic:
SPD1 - SPD2 - SLD1 - SLD2 -TSM1 - TSM2 - SOFT
involves a complete operation at reduced speed.
The PRG message is displayed.

5.3) RADIO (

RAD

)

MENU

FUNZIONE

PP

By selecting this function, the receiver goes in waiting (

Push

) for a transmitter code to assign to the step-step function. 

Press the key of the transmitter to assign to this function. 
If the code is valid, it is memorised and the message 

OK

 is displayed

If the code is not valid, the message 

Err 

is displayed

2Ch

By selecting this function, the receiver goes into waiting (

Push

) for a transmitter code to assign to the second radio channel. 

Press the key of the transmitter to assign to this function. 
If the code is valid, it is memorised ad the 

OK

 message is displayed

If the code is not valid, the message 

Err 

is displayed.

ped

By selecting this function, the receiver goes into waiting (

Push

) for a transmitter code to assign to the pedestrian opening function (see 

parameter TPED).
Press the key of the transmitter to assign to this function. 
If the code is valid, it is memorised ad the 

OK

 message is displayed

If the code is not valid, the message 

Err 

is displayed.

CLR

By selecting this function, the receiver goes into waiting (

Push

) for a transmitter code to erase from the memory. 

If the code is valid, it is erased and the message 

OK 

is displayed

If the code is not valid or not present in memory, the message 

Err 

is displayed

RTR

Completely erases memory of the receiver. Confirmation of the operation is requested. 
By selecting this function the receiver goes into waiting (

Push

) for a new PGM pressure to confirm the operation. 

At end of erasing the 

OK

 message is displayed

5.4) CYCLES NUMBER (

NMAN

)

Displays the number of complete cycles (open+close) carried out by the automation. 
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 

0012 

>>> <PG> 

3456

: made 123.456 cycles.

Содержание 1-10010

Страница 1: ...L8543262 02 2020 rev 1 HYBRA 24 IT EN DE FR ES PL ...

Страница 2: ...115V 100 250 Vac POWER INPUT SELECTION GND GND M1 M2 LAMP 24Vdc Lock 12Vdc 10W 5s 24Vdc 500mA max COM PHOTC ENC 1 ENC 2 BAR PHOTO STOP CLOSE PED P P AUX1 OPEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 JMP1 JMP1 DAS Open DAS N C JMP1 BAR Close DAS 8K2 8k2 BAR 26 27 28 29 30 31 32 33 36 37 34 35 24V M4 1 ...

Страница 3: ...4 5 6 26 27 28 29 30 31 HYBRA24 M1 M2 ENC1 ENC2 K R B G W K R B G W M1 M2 K R B G W ENC ENC ENC M 24 M 24 Bianco White Weiß Blanc Blanco Biały Verde Green Grün Vert Verde Zielony Marrone Brown Braun Brun Marrón Brązowy Rosso Red Rot Rouge Rojo Czerwony Nero Black Schwarz Noir Negro Czarny AUX1 SCA AUX1 0 AUX2 SCA AUX2 0 24Vdc 500mA max SCA 24Vdc 3W max 11 12 34 35 36 37 24Vdc 500mA max 9 10 11 12 ...

Страница 4: ... L N Service Zone Light 230Vac Relè 24Vdc 24Vdc 500mA max 11 12 AUX1 2 24Vdc 500mA max 9 10 11 12 Service Zone Light 230Vac L N Relè 24Vdc 34 35 36 37 24Vdc 24Vdc COM NC NO RX1 TX1 24Vdc 24Vdc COM NC NO RX2 TX2 11 24Vdc COM PHOT COM PHOT C 24Vdc 12 11 12 13 18 13 19 9 10 9 10 test1 on test2 ON AUx1 4 AUx1 4 AUX1 AUX1 4 5 ...

Страница 5: ...tst1 tst2 tstm rem PRG spd2 99 PRG PRG PRG sld2 pmo1 sld1 30 20 30 PRG PRG PRG PRG PRG PRG PRG PRG pmc1 pmo2 pmc2 pso1 pso2 psc2 tdmo 20 20 20 20 psc1 20 20 2 20 PRG PRG PRG PRG PRG tdmc tloc seav sear tinc aux1 aux2 2 tls 5 0 0 60 PRG 250 PRG 0 PRG 1 Schema menu di programmazione Menu programming layout Diagramm Programmiermenü Menu de programmation Menú de la carta de programación Układ menu pro...

Страница 6: ...cisnąć przycisk PG Premere simultaneamente e Press simultaneously keys and Gleichzeitig und drücken Presser simultanément et Presionar simultáneamente y Naciskać jednocześnie i Selezionare il valore desiderato con i pulsanti e Increase decrease the value with keys and Mit den Tasten und kann man eingerichtete Werte ändern Régler la valeur désirée avec les touches et Establecer con las teclas y el ...

Страница 7: ...roducts to become null and void All the mechanical and electrical parts composing automation must meet the requirements of the standards in force and outlined by CE marking ELECTRICAL SAFETY An omnipolar switch section switch with remote contact opening equal to or higher than 3mm must be provided on the power supply mains Make sure that before wiring an adequate differential switch and an overcur...

Страница 8: ...t for connection of back up batteries accessory HYBRA 24 Terminal No Function Description 1 2 Motor 1 Connection motor 1 24VDC 16A max 3 4 Motor 2 Connection motor 2 24VDC 16A max 5 6 Flashing light Connection flashing light 24VDC 15W max 7 8 Lock Output 12Vdc 10W power supply for electric lock 7 0V 8 12V 9 10 AUX1 N O contact free from voltage can be configured via the AUX1 parameter as Open gate...

Страница 9: ...he central unit performs a sequence of operations single partial openings full openings and closings at different speeds and so on D u r i n g this phase the display will show some acronyms that indicate the operation that is being performed at that time OPM1 2 motor 1 or 2 in opening phase CLM1 2 motor 1 or 2 in closing phase If the motor movement is opposite to what is indicated on the display s...

Страница 10: ...n is adjusted in the closing phase at normal speed Motor 1 1 99 50 PMo2 The anti crash device amperometric sensor operation is adjusted in the opening phase at normal speed Motor 2 1 99 50 PMc2 The anti crash device amperometric sensor operation is adjusted in the closing phase at normal speed Motor 2 1 99 50 Pso1 The anti crash device amperometric sensor operation is adjusted in the opening phase...

Страница 11: ...tomatic closing disabled ON IbL Enables or disables condominium function On condominium function enabled The step by step impulse or transmitter impulse has no effect during the opening phase Off condominium function disabled OFF ibca The multi flat function is enabled or disabled during the TCA counting On the bloc of flat function is enabled The Step by Step signal or the transmitter signal has ...

Страница 12: ... On Check enabled If the check has a negative result no manoeuvre is commanded Off Check disabled OFF rem Enables or disables remote radiotransmitters learning as indicated in the paragraph Remote transmitters learning On Remote learning enabled Off Remote learning not enabled OFF CAUTION Any change to one of these parameters logic SPD1 SPD2 SLD1 SLD2 TSM1 TSM2 SOFT involves a complete operation a...

Страница 13: ...ter can be changed with keys and press OK to confirm the flashing character then confirm the following one after typing in the 4 characters a confirmation message CONF appears after a few seconds the code 0000 appears again the previously stored protection code must be reconfirmed in order to avoid any accidental typing in If the code corresponds to the previous one a confirmation message OK appea...

Страница 14: ...error Check motor 1 connections Err2 Motor 2 circuit checking error Check motor 2 connections Err3 error fault power circuit Request technical assistance and eventually replace control unit Err4 PHOTA photocell checking error Check connections PHOT A photocell alignment or presence of obstacles Err5 PHOTC photocell checking error Check connections PHOTC photocell alignment or presence of obstacles...

Страница 15: ...n 3 Zuletzt die beiden als Scharnier dienenden Schrauben lockern aber nicht ausbauen damit der Deckel geöffnet werden kann 1 Presser les deux ailettes latérales pour décrocher les deux cache vis 2 Enlever les deux vis sur le côté d ouverture désiré 3 Desserrer les deux vis faisant fonction de charnière sans les enlever de manière à permettre l ouverture du convercle 1 Presionar las aletas en los l...

Страница 16: ...AUTOMATISMI CAB Srl Via della Tecnica 10 z i 36010 Velo d Astico VI Italia Tel 0445 741215 Fax 0445 742094 info automatismicab com www automatismicab com ...

Отзывы: