INSTRUCTIONS FOR THE CORRECT DISPOSAL OF THE PRODUCT FOR THE PURPOSE AND EFFECT OF EUROPEAN COMUNITY DIRECTIVE

2002/96/EC:

At the end of its useful life the product must not be disposed of with domestic waste.

It may be delivered to the relevant separate waste collection centres prepared by municipal administrations, or at retailers that supply this service.

Disposing of the product separately prevents possible negative consequences for the environment and for health, deriving from inadequate disposal. It

also allows the recovery of materials of witch it’s made up in order to obtain an important saving of energy and resources. 

In order to point out the obligation to dispose of the electromedical appliances separately, the product has the sign of the crossed mobile waste container

applied to it.

TECHNICAL CHARACTERISTICS

TYPOLOGY (MDD 93/42/EEC)

Class IIa Medical Device

MODEL

MOBILE

POWER SUPPLY

100÷240V~ 50/60Hz with power supplier in equipment (

model FUHUA 

UE20-120167SPA1 or UE24WCP-120167SPA

) or with car plug cable 

(provided with unit) or 12V dc with rechargeable batteries NI-MH typeAA – 1.2V 

(not provided with unit)

ABSORBED CURRENT

1.2A

ABSORBED POWER

38.5 VA (with power supplirer mod. UE20-120167SPA1 or UE24WCP-120167SPA)

OPERATIONAL PRESSURE

80 kPa (0.8 Bar)

MAXIMUM PRESSURE

200 kPa (2.0 Bar)

OPERATIONAL FLOW

4.0 l/min

MAXIMUM FLOW

12 l/min

MMAD (EN 13544-1)

m

GSD (EN 13544-1)

2.89

AEROSOL OUTPUT (EN 13544-1)

258.0 

l

OUTPUT RATE (EN 13544-1)

32.6 (

l/min) 1 min

NEB-RATE

0.35 ml/min (4ml NaCl 0.9%)

WEIGHT

0.560 Kg

DIMENSIONS

140 (D) x 96 (W) x 74 (H) mm

OPERATION

30 ON / 30 OFF

MAXIMUM NOISE LEVEL

50 dB (A)

MAXIMUM NEBULIZER CAPACITY

6 ml

WORKING CONDITIONS

Room temperature:

10 ÷ 40 °C

Room humidity percentage:

10 ÷ 95 %RH

CONSERVATION AND TRANSPORT CONDITIONS

Room temperature:

-25 ÷ 70 °C

Percentuale umidità ambiente:

10 ÷ 95 %RH

GRAPHIC OF NEBULIZED PARTICLES DISTRIBUTION ACCORDING TO EN 13544-1

C U T   O F F  

(

µm

)

MMAD = Mass Median Aerodynamic Diameter
GSD = Geometric Standard Deviation

SYMBOLS

www.nebulisercentre.co.uk

Содержание Mobile

Страница 1: ...PORTABLE COMPRESSOR NEBULIZER INSTRUCTION MANUAL www nebulisercentre co uk...

Страница 2: ...environments which have anaesthetic mixtures inflammable with air oxygen or nitric oxide Don t touch MOBILE with wet hands and always prevent the appliance is not touched by liquids The use of this d...

Страница 3: ...PPLY 100 240V 50 60Hz with power supplier in equipment model FUHUA UE20 120167SPA1 or UE24WCP 120167SPA or with car plug cable provided with unit or 12V dc with rechargeable batteries NI MH typeAA 1 2...

Страница 4: ...st IEC EN 61000 4 4 2kV power supply Mains power quality should be that of a typical commercial environments or hospital Surge IEC EN 61000 4 5 1kV differential mode Mains power quality should be that...

Страница 5: ...manual Before proceeding to the cleaning and maintenance operations and at the end of each use remember to turn off the switch and disconnect MOBILE from electrical power supply WARNING When MOBILE op...

Страница 6: ...in a dry and cool place and protected by atmospheric agents Never use wet or overheated batteries Insert batteries with negative and positive poles correctly oriented please see indications shown in...

Страница 7: ...15 20 C Operations by not rechargeable alkaline batteries not included In case of extreme necessity this device can also be used with non rechargeable alkaline batteries To be able to use MOBILE with...

Страница 8: ...mponent of the nebulizer except air tube removing medication residual and possible impurities Clean all parts in warm water Rinse thoroughly making sure that all deposits are washed away and let dry D...

Страница 9: ...E TO NAY DEVICE THAT HAS BEEN TAMPERED STANDARD ACCESSORIES ACCESSORIES HI FLO KIT Nebulizer HI FLO adult mask pediatric mask air tube mouth piece nosepiece AC DC Adapter Power Cord for AC DC adapter...

Отзывы: