Bullard CC20 Respiratory Systems provide a continuous flow of air
from a remote air source via airline. The flow of air is delivered
to the respirator wearer through a patented air delivery system.
CC20 Series respirators offer protection from airborne contami-
nants that are not immediately dangerous to life or health (IDLH),
or that do not exceed concentrations allowed by applicable OSHA,
MSHA, EPA, NIOSH or ACGIH regulations and recommendations,
or any other applicable regulations for continuous flow airline
respirators.
CC20 Series airline respirators are approved by NIOSH
(TC-19C-154 Type C). Bullard has determined that these respira-
tors may be used to provide respiratory protection in general
purpose applications, including pharmaceutical manufacturing,
chemical and pesticide handling, tank cleaning, spray painting and
other industrial or agricultural applications in which hazardous
compounds are present.
Bullard hoods are available in 13 different styles and sizes, includ-
ing a loose-fitting facepiece style with a partial facial seal. Bullard
hoods will accommodate limited facial hair without compromising
the level of protection. Facial hair must not interfere with or
protrude under the facial seal on the 20LF or 20LF2 style hoods.
The hood covers are held in place by snap-in replaceable suspen-
sions or, in the case of the loose-fitting facepiece hoods, a sewn-in
elastic suspension. Breathing air is supplied from a breathing tube
connected to the back of the hood.
CC20 Series respirators are compatible with breathing air sources
such as breathing air compressors or Bullard Free-Air
®
Pumps.
Bullard offers the appropriate approved breathing tube, flow
control device and air supply hose to connect the CC20 Series
respirator to these breathing air sources.
CC20 Series respirators are approved by NIOSH for use with
optional Bullard climate control devices. Contact Bullard or its
local authorized distributor for more information about these and
other accessories for CC20 Series respirators.
All Bullard parts must be present and properly assembled to
constitute a NIOSH approved respirator.
For technical assistance, contact Bullard Technical Support at
877-BULLARD (285-5273) or 859-234-6616.
Note
Bullard CC20 hoods are also NIOSH approved for cer-
tain PAPR configurations. Please refer to your
Bullard PAPR manual or call Customer Service at
877-BULLARD (285-5273).
Read all instructions and warnings before using these respirators. Failure to follow these instructions could result in death or serious injury.
Save this manual for future reference.
The CC20 Series Airline Respirators are not approved for abrasive blasting.
The CC20 respirator’s air source must supply clean, breathable air, Grade D or better, at all times. The CC20 respirator does not purify air
or filter out contaminants. Connecting the CC20 respirator to a line supplying nitrogen or other harmful gases could cause death or serious
injury.
WarNiNg
approval Label
...................................................................................... 2-3
Component Concept - CC20
................................................................ 4
Warnings and Limitations
................................................................ 5-6
operations
Protection .................................................................................................... 6
Breathing Air Requirements ....................................................................... 7
Breathing Air Pressure ............................................................................... 7
Breathing Air Supply Hoses and Hose Fittings .......................................... 7
Breathing Air Pressure Table ..................................................................... 8
respirator assembly
Adjusting and Installing Headband
in Respirator Hood ...................................................................................... 9
Adjusting and Installing Hard Hat
in Respirator Hood .................................................................................... 10
Installing Breathing Tube Assembly in
Respirator Hood ........................................................................................ 11
Using Climate Control Devices .................................................................. 11
respirator Use
Donning .......................................................................................................12
Removing .....................................................................................................12
inspection, Cleaning and Storage
Hood and Headband .................................................................................. 13
Hard Hat .................................................................................................... 14
Breathing Tube ......................................................................................... 14
Flow Control Valve/Climate Control Device .............................................. 14
Air Supply Hoses ....................................................................................... 14
Storage ...................................................................................................... 14
Parts and accessories
..................................................................... 15-18
return authorizations
......................................................................... 19
table of Contents
type C Continuous-Flow Class – approval No. tC-19C-154
CC20 Series airline respirator
User Manual