- 11 -
parameter and button is as follows.
In this interface, the pressure correction table is composed of feedback voltage and actual pressure.
The feedback voltage is the output voltage of the built-in pressure sensor, and the actual pressure
(kN) is the pressure sensor indication (kg) × 9.8.
Measuring method of pressure correction table:
①
.
Place the 5T pressure sensor on the press so that it can be overwhelmed when the press rises,
click the up button to rise until the sensor is about to be overwhelmed;
②
.
In the [Pressure Correction] interface, you can fine-tune the pressure, turn the electronic
handwheel to the right, the press rises, and turn the electronic handwheel to the left, the press
drops. And record the feedback voltage and pressure sensor reading (kg) at this time.
③
.
Obtain five sets of data according to the method of step
②
, input the data into the pressure
correction table in the order of the feedback voltage from small to large, and click the "parameter
download" button to save the data to obtain the pressure correction table.
Figure 5-2 pressure correction interface
[Feedback voltage]: Display the output voltage of the pressure sensor;
[Status code]: The working status code indicates the current working status of the equipment or the
fault that has occurred. For details, refer to Appendix 1, or directly query in the system settings;