PN 060914-000
Revision C, October 2001
Page 2-12
© 2001, C-COR.net Corporation
Figure 502-1. Integrated Fan/Power Supply (Dual Output Version) Rear Panel
Figure 502-2. HX1281EC Equipment Shelf Rear View
Note:
Steps 5 through 8 connect the -48 VDC output(s) of the Integrated Fan/Power
Supply to the HWX Equipment Shelf (HX1281EC or HX2281EC) input terminal blocks
(refer to Figures 502-1 and 502-2).
5. Single or redundant Integrated Fan/Power Supply?
If a
single
output supply (HW-PSFAN
-1-
xxx), continue to step 6.
If a
redundant
output supply (HW-PSFAN
-2-
110), go to step 7.
6. Connect the Fan/Power Supply terminal block Power Supply A -48V to either HWX
Equipment Shelfs rear panel input terminal block -48VDC 5A (A or B). To make
wire connections, go to step 8.
7. Connect the Fan/Power Supply terminal block Power Supply A -48V to either HWX
Equipment Shelfs rear panel input terminal block -48VDC 5A (A or B). Then connect
the Power Supply B -48V terminal block to the
other
HWX Equipment Shelf rear
panel input terminal block -48VDC 5A. To make wire connections, continue to step 8.
Terminal Block A
Terminal Block B
DLP-502
Page 2 of 3
Содержание Optiworx HW Series