PROTECTION & SAFETY
17
2021/07 - Version: C - Code : 34681
6.1.
Slaving
Slaving is possible via a potential free dry contact (refer to the diagram on the previous page and the wiring
diagram).
Slaving can be associated with the filtration pump, booster pump, etc.
The connection at the relay in the automatic cover electrical panel is normally open (NO). This must be changed
to normally closed (NC) to carry out slaving.
Filtration panel wiring diagram:
6.2.
Stardeck deck box
IMPORTANT
The pit should be ventilated to avoid problems with humidity in the motor and the deck box.
In the deck box, connect the quick male connectors of the motor to the female connectors on the white wall of
the compartment. The revolution counter connector has three contacts (C/S/A), the rotation direction connector
features 2 (+/-).
Wiring of the motor sensor connector is provided for information purposes, it is pre-wired in the
factory.
Connector Wire Terminal
after
11/2019
Terminal
before
11/2019
L
3
C
C
Earth
1
A
T
N
2
S
A
Once correct operation of the cover has been verified
(direction of rotation of the axle, memorisation of ends
of travel, etc.), and the deck box has been fixed, it can be filled with the removable waterproof gel (supplied) to
protect the contacts against humidity.
If the rotation of the axle is incorrect, invert it as shown in the section describing the printed circuit board.