WF-WK100
WiFi Wireless
Cost-effective
Inclinometer
Bewis Sensing Technology LLC
www.bwsensing.com
Tel:
+86 189
2129 2620
1-6-1
Set sleep cycle
The format of the sleep wake-up period is dHHmmss, d is the number of days, HH is the hour, mm is the
minute, and ss is the second. The 0 on the left can be omitted. For example, 123456 represents 0 days, 12
hours, 34 minutes, and 56 seconds. The maximum sleep period is not allowed to exceed 7 days. When the
sleep wake-up period is less than or equal to the wake-up hold time, sleep is disabled. The default is 0, sleep
is prohibited.
Send: WAKEUperiod
Or WP+period
Return: OK
1-6-2
Set wake-up hold time
The format of the wake-up hold time is dHHmmss, d is the number of days, HH is the hour, mm is the
minute, and ss is the second. The 0 on the left can be omitted. For example, 123456 represents 0 days, 12
hours, 34 minutes, and 56 seconds. When sleep is allowed and the wake-up hold time is set to 0, the sensor
will sleep immediately after automatically outputting data through WLAN for the first time, or force sleep
when it fails to send any data within 60 seconds. The default is 10
Send: WAKtime
Or WT+time
Return: OK
1-6-3
Set the threshold for wake-up changes
The range is 0-2047, and the unit is mg (one thousandth of the acceleration due to gravity, to be precise,
2000/2048=0.9765625mg). When the sensor is absolutely level, if the threshold is set to 500mg, the
threshold will be reached when the inclination angle is greater than or equal to
arcsin(500mg/1000mg)=30°. The default is 200mg.
Send: MOTIOthreshold
Or MH+threshold
Return: OK