background image

WF-W

K10

0

WiFi Wireless 

Cost-effective

 Inclinometer 

 Bewis

 

Sensing

 

Technology

 

LLC

     

    

www.bwsensing.com      Tel

+

86 189 

2129 2620

e Enter the HEX command or string command, and click Send, you can control via WLAN, as shown in the 

figure:

 

Note:

 If the Socket is disconnected abnormally or the network is abnormal, it may cause the listening to stop, 

please pay attention to restart the listening.

Quick start

1  

Basic data collection

a  

Connect the computer to the router to which the sensor will be connected via WLAN or Ethernet.

Содержание WF-WK100

Страница 1: ...WF WK100 WiFi Wireless Cost effective Inclinometer Technical Manual...

Страница 2: ...network abnormalities and server maintenance The sensitive mechanism adopts the latest technology the tilting unit of the micro electromechanical production process small size low power consumption co...

Страница 3: ...tion Connectors Protection level Housing material Install Aviation plug IP65 Magnesium aluminum alloy anode oxidation Three M4 screws Measuring range Measuring axis Accuracy Resolution Cross axis erro...

Страница 4: ...ngle and the Root mean square RMS of the measured angle of the sensor 16 times Electrical Specifications Network Topology Bewis Sensing Technology LLC www bwsensing com Tel 86 189 2129 2620 Supply vol...

Страница 5: ...o actual size 109 97 65 36 53 4 Hole 105 Electrical connections Definition of Aviation Plug Wiring RED 1 4 2V Color function BLACK 3 GND GREEN 4 YELLOW 5 RX TX Bewis Sensing Technology LLC www bwsensi...

Страница 6: ...axis of the measured object shouldn t generate the angle shown in E When installing the bottom cable of the sensor should be kept parallel or orthogonal to the rotation axis of the measured object Thi...

Страница 7: ...tp www bwsensing com cn upload userfile Bewis Sensing iCOM serial port debugging assistant 2 0_ 9_ zip Instructions a Open the software and automatically connect to the serial port If there are multip...

Страница 8: ...ick Send 1 2 Open source software PuTTy This tool does not support the use of HEX commands for sensor configuration HEX commands are not necessary but special information can be marked with different...

Страница 9: ...ill cause command errors 2 Network debugging tools Note Network debugging tools generally only transmit data to a single or a small number of network connections When the number of sensors is large it...

Страница 10: ...al IP and local port c Check HEX Display and HEX Send when using HEX commands for configuration or receiving automatic output data in HEX format do not check HEX Display when using string commands for...

Страница 11: ...ommand and click Send you can control via WLAN as shown in the figure Note If the Socket is disconnected abnormally or the network is abnormal it may cause the listening to stop please pay attention t...

Страница 12: ...address is to set the receiver IP of the sensor b Refer to section 2 1 in Debugging Method to open the network debugging tool SSCOM select TCPServer as the port number set the port to be listened to...

Страница 13: ...w access c Use a serial cable USB to TTL serial port to connect the sensor and the computer Refer to section 1 1 in Debugging method to open the iCOM serial port debugging tool select the COM port con...

Страница 14: ...al port tool receives the following information indicating that the sensor has been started normally e Send any identifiable string command HELP is used here to make the sensor exit silent mode the co...

Страница 15: ...assword is the WLAN password these two parameters are the same as in step a For command details refer to section 1 7 1 in String Command g Set Socket information and send the command NETWORK SOCKET TC...

Страница 16: ...o several seconds the network connection is established and the received data can be seen in the network tool SSCOM For the default data analysis please refer to section 2 2 3 of HEX Command If the da...

Страница 17: ...frequency After the sensor has been able to send data to the receiving device via WLAN perform the following operations to configure the sensor to work in low power consumption Assuming that the WLAN...

Страница 18: ...ending the first data via WLAN If the network connection uses the UDP protocol it is recommended to set a certain length of wake up hold time and set a shorter automatic output period to avoid difficu...

Страница 19: ...ough the following operations Please ask the sales staff for the specific Beiwei Cloud account and sensor ID allocation Note that when sending sensor data to Beiwei Cloud the sensor ID is a 9 digit BC...

Страница 20: ...m Tel 86 189 2129 2620 c Send AOUT PERIOD 5000 and set the sensor s automatic output frequency to 5 seconds slightly higher than 5 seconds is recommended For command details refer to section 1 1 1 in...

Страница 21: ...nometer Bewis Sensing Technology LLC www bwsensing com Tel 86 189 2129 2620 e Send NETWORK SOCKET UDP 47 103 38 169 12000 and set the target IP and port of the sensor to the IP and port of Beiwei Clou...

Страница 22: ...86 189 2129 2620 g Log in to the Beiwei Cloud website at http 47 103 38 169 Log in with the provided account and password Select the sensor corresponding to the ID in the Data Table column on the lef...

Страница 23: ...ode After the sensor is powered on it enters the silent mode and there is no echo when sending a string command but all commands are valid After sending any recognizable string command it will automat...

Страница 24: ...lowest is 0 After each data frame there is a line break The data in JSON string format is as follows Addr 00000001 X 0 4010 Y 0 7471 Temp 27 26 Batt 9 Date 20 09 21 Time 10 23 20 This data is in full...

Страница 25: ...K 1 1 5 View all automatic output configurations Send AOUT STATUS Or AOUT S Return configuration information and OK 1 2 Enter silent mode EXIT After entering the silent mode the sent data will no long...

Страница 26: ...the save command SAVE GENERAL or SAVE ALL to save 1 4 1 Set the serial port baud rate The recommended serial port baud rate range is 2400 460800bps The baud rate changes after receiving the return in...

Страница 27: ...L D date Return OK 1 4 4 Set the sensor date format The optional formats are year month day yyMMdd day month year ddMMyy and month day year MMddyy All date formats are the same as those set here and t...

Страница 28: ...of sports wake up and minimum exercise duration for sports wake up The sleep function is only valid when the sleep wake up period is greater than the wake up hold time and the WLAN automatic output i...

Страница 29: ...number of days HH is the hour mm is the minute and ss is the second The 0 on the left can be omitted For example 123456 represents 0 days 12 hours 34 minutes and 56 seconds When sleep is allowed and t...

Страница 30: ...seconds ms and the accuracy is 80ms The default is 400ms Send LOWPWR MOTIONTIME time Or LOWPWR MT time Return OK 1 6 5 View all low power configurations Send LOWPWR STATUS Or LOWPWR S Return configura...

Страница 31: ...Return OK 1 7 2 Set Socket information The protocol can be TCP or UDP TCP has higher reliability and theoretically no packet loss UDP has higher real time performance and efficiency but packet loss ma...

Страница 32: ...sor restarts 1 9 Save You can save all the configuration of a module or all modules and the configuration will remain after power off Send SAVE ALL or AOUT or GENERAL or LOWPWR or NETWORK or SENSOR or...

Страница 33: ...nfiguration and information Send SENSOR STATUS Or SENSOR S Return All configuration and information and OK 1 1 11 Display configuration SHELL The following commands can configure the sensor s echo mod...

Страница 34: ...tly the same In minimalist mode the echo is completely turned off and any unrecognized commands will not cause error output but identifiable but invalid commands will still cause error output This mod...

Страница 35: ...string commands These commands only provide a relatively efficient alternative and are compatible with some Beiwei upper computers The following 0x means that the data is hexadecimal data Please do no...

Страница 36: ...length 1 byte Address code 4 byte Command 1 byte Data field 0 byte Checksum 1 byte 0x77 0x07 0x02 Response Command Identifier 1 byte Data length 1 byte Address code 4 byte Command 1 byte Data field 4...

Страница 37: ...l bit BCD code 2 2 4 Set relative absolute zero point Command 77 08 00 00 00 00 05 00 0D Identifier 1 byte Data length 1 byte Address code 4 byte Command 1 byte Data field 1 byte Checksum 1 byte 0x77...

Страница 38: ...e two axis angle temperature and power data in HEX format refer to Section 2 2 3 of HEX Command 0x01 is the X axis angle in HEX format refer to section 2 2 1 of HEX Command 0x02 is the Y axis angle in...

Страница 39: ...storage otherwise the previously saved configuration will be restored after reset 2 2 11 Set sleep cycle Command 77 0B 00 00 00 00 46 00 00 00 00 51 Identifier 1 byte Data length 1 byte Address code...

Страница 40: ...BCD code dd means days HH means hours mm means minutes and ss means seconds 2 2 15 Set the exercise threshold for exercise wake up Command 77 09 00 00 00 00 42 02 00 4B Identifier 1 byte Data length 1...

Страница 41: ...d 1 byte Checksum 1 byte 0x77 0x08 0x8A 0x00 Set successfully 0xFF Setup failed 2 2 18 Reset Command 77 07 00 00 00 00 0E 15 Identifier 1 byte Data length 1 byte Address code 4 byte Command 1 byte Dat...

Страница 42: ...he automatic output cycle is 0 the data will only be output once every time it restarts or wakes up 3 WLAN can t connect Maybe the WLAN signal is not covered or there is no wireless signal that the se...

Страница 43: ...s Sensing Technology LLC www bwsensing com Tel 86 189 2129 2620 Enterprise quality system standard ISO9001 2015 standard certificate number 23919Q10455R0S CE certification certificate number M 2019 10...

Страница 44: ...ogy LLC Address Building 30 No 58 Xiuxi Road Binhu District Wuxi City Jiangsu Province China Tel Whatsapp 86 189 2129 2620 Email sales bwsensing com Website www bwsensing com WF WK100 WiFi Wireless Co...

Отзывы: