3.7.3 Detector Keypads
Figure 4
KEYS DESCRIPTION
Detector switch-on key.
If pressed at the same time, they allow detector
manual switching off.
Legend of Figure 4:
A -
Green LED on:
detector battery is under charge
B -
Red LED steady on:
detector is on
Red LED flashing:
detector is flat (when battery residual charge is
lower than or equal to 30%); it will turn off after
a few minutes
3.7.4 LED indicating Levelling and Tolerance during Adjustment
Detectors series SPEEDLINER 8050WS and SPEEDLINER 9080WS (see par.3.7.1 and 3.7.2)
are equipped with LED indicators for their correct levelling (for levelling function in detectors
SPEEDLINER 9080WS a display is used, see par. 3.7.3) and for tolerance during adjustment..
Levelling indicator
RED LED on
detector is not levelled
RED LED flashing and GREEN LED steady on
detector is close, but not levelled
GREEN LED ONLY is flashing
detector is levelled
RED LED flashing and GREEN LED steady on
detector is close, but not levelled
RED LED on
detector is not levelled
Tolerance indicator during adjustment
GREEN LED flashing
measurement is within tolerance, exactly at the centre
RED LED flashing and GREEN LED steady on
measurement is within
tolerance
RED LED on
measurement is NOT within tolerance
Note: during front adjustment, if you want to observe tolerance onto LEDs, take the red selection
frame on the value you are adjusting (see 8.12 on page 36).
During rear adjustment, on the contrary, tolerance is indicated both on horizontal LEDs (toe) and
vertical LEDs (camber).
LEDs on
FRONT
detectors
Tolerance
TOE or
CAMBER or
CASTER
LEDs on
REAR
detectors
TOE tolerance
Levelling (SL8050WS, only)
CAMBER tolerance
Alphanumeric display (mod. SL9080WS,
ONLY) - It shows :
- battery charge in %
- electronic level in the relevant phase
- Run-Out status in the relevant
phase
(A) Green LED
(B) Red LED