Installation | 5
0870237638_LR0110-0580A_-_IM_en
11 / 32
5.2.1 Suction Connection
NOTICE
Ingress of foreign objects.
Risk of damage to the machine!
If the inlet gas contains foreign solid particles:
• Install a suitable inlet screen (smaller than 0.2 mm mesh size) upstream of the ma-
chine.
Connection size(s):
– DN125 PN10 (for LR 0110 A and LR 0140 A)
– DN150 PN10 (for LR 0210 A and LR 0300 A)
– DN200 PN10 (for LR 0420 A)
– DN250 PN10 (for LR 0580 A)
5.2.2 Discharge Connection
NOTICE
Too high elevation or lack of separation.
Will cause back pressure and possible drive motor overload!
• The discharge piping on machines without integral separator manifold should not ex-
ceed an elevation of more than 1000 mm above the discharge flange (OUT) of the
machine until the liquid is separated.
Connection size(s):
– DN125 PN10 (for LR 0110 A and LR 0140 A)
– DN150 PN10 (for LR 0210 A and LR 0300 A)
– DN200 PN10 (for LR 0420 A)
– DN250 PN10 (for LR 0580 A)
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line or use it as a pressurised air source.