2 | Product Description
6 / 32
0870237638_LR0110-0580A_-_IM_en
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
Gas
Discharge
Gas Discharge
Gas and
Liquid
Discharge
Gas Discharge
Liquid
Discharge
Drain
Drain
Drain
Drain
Suction
Suction
Suction
Suction
Makeup
Overflow
Makeup
Overflow
IDS
GV
PG
SSC
SSI
CG
OPC
OPI
ADV
OPD
GPD
ICV
SV
LLI
HX
ADV
Automatic drain valve
CG
Compound pressure gauge
GPD
Gland packing drain
GV
Vacuum gauge
HX
Heat exchanger
ICV
Inlet check valve
IDS
Integral discharge separator
LLI
Liquid level indicator
OPC
Operating liquid control
OPD
Operating liquid drain
OPI
Operating liquid inlet
PG
Pressure gauge
SSC
Shaft seal flushing control
SSI
Shaft seal flushing inlet
SV
Separator vessel
2.1 Description of Figures 1 - 4
• Figure 1 shows the general standard once through arrangement with integral dis-
charge separator manifold.
• The arrangements of figure 2 (partial recirculation) and 3 (total recirculation) are for
handling combustible, corrosive and explosive gases as well as the gas which is re-
quired to be recycled. If the working liquid is recirculated in the system as shown in
figure 3, then a heat exchanger should be used for cooling the liquid.
• Figure 4 (option for LR 0420 A and LR 0580 A only) shows the arrangement where
gas and water leave from the side flange of the vacuum pump and discharge directly
into the gutter.