DN 40 ISO KF for NS 0070-0160 C
In the case of long exhaust lines the line cross-section should be larger
than the exhaust flange to prevent a drop in the performance of the
vacuum pump. If you have any doubts, contact your Busch
representative.
A silencer (SI) (optional accessory) can be fitted to the pump discharge
to avoid pulsation and sound transmission into the exhaust line.
Cooling water connection
The cooling water is generally connected with a hose.
Connection diameter:
–
cooling water inlet: 3/8'' NPT
–
cooling water outlet: 3/8'' NPT
Nitrogen connection
Connection diameter: 1/4'' NPT
Electrical connection/ Checks
l
Make sure that the regulations of the Electromagnetic
Compatibility Directive 20
1
4/
3
0/E
U
as well as standard EN
norms, safety directives and especially local and national
regulations are observed (this is the responsibility of the
manufacturer of the system into which the vacuum pump is
integrated according to the declaration of conformity).
l
Make sure that the mains power supply corresponds to the data on
the nameplate(s) of the motor(s).
l
Make sure that an overload cut-out according to EN 60204-1 is
provided for the motor(s).
l
Make sure that the drive of the vacuum pump is not disturbed by
any electric or electromagnetic interferences. If you have any
doubts, contact your Busch representative.
Installation
Assembly
l
Make sure that the “necessary installation instructions” are
followed.
l
Fasten or install the pump at its final installation site.
Electrical connection
WARNING
Risk of electrocution, risk of damage.
Electrical installation must be performed by a suitably qualified
electrician who knows and follows the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100,
- IEC Report 664 or DIN VDE 0110,
- VBG 4 or corresponding national regulations on accident
prevention.
CAUTION
The circuit diagrams described below conform to the standard.
Other circuit diagrams might be used. This depends on the
particular order and the market.
Risk of damage to the motor!
Check the connection of the motor inside the terminal box
according to the circuit diagram.
WARNING
The operating rotational speed of the drive motor must correspond
to the pump's nameplate value. Do not exceed the mentioned
rotational speed.
n
max
= 3000min
-1
-> 50Hz +/- 2%
n
max
= 3600min
-1
-> 60Hz +/- 2%
Risk of damage to the vacuum pump!
l
Connect the motor electrically.
l
Connect the earth lead.
Installation and Commissioning
NS 0070-0160 C
Page 8
0870570353 (En)
Cooling water and nitrogen connections
Ateliers Busch S.A.
Zone Industrielle
CH-2906 Chevenez
Vacuum Pump
NS 0160 C
S/N = C1405009999
p
abs
= 0.03 hPa (mbar)
V
max
= 160 m /h
3
.
n
max
= ***** min
Oil = Busch YLC 250 B
-1
m = 250 kg
Oil quantity = 2 L
Made in
Switzerland
Year 2014
n
max
= 3000 min
or
-1
n
max
= 3600 min
-1
T1
T3
T2
T4
T6
T5
PTC