11 | Troubleshooting
32 / 36
0870557375_NC2000B_VR_Ex_A0002_IM_en
The machine runs too hot.
Insufficient cooling.
• Make sure to comply with
the cooling liquid require-
ments, see
Cooling Liquid
Connection [
►
13]
.
Ambient temperature too
high.
• Observe the permitted
ambient temperature, see
Technical Data [
►
33]
.
Temperature of the process
gases at the inlet too high.
• Observe the permitted
gas inlet temperature, see
Technical Data [
►
33]
.
Oil level too low.
• Top up oil.
The oil is black.
Oil change intervals are too
long.
• Drain the oil and fill in
new oil, see
Oil Change
[
►
26]
.
The machine runs too hot.
• See problem "The ma-
chine runs too hot".
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.
Содержание COBRA ATEX
Страница 35: ...Note...