8 | Overhaul
30 / 36
0870557375_NC2000B_VR_Ex_A0002_IM_en
8
Overhaul
NOTICE
Improper assembly.
Risk of premature failure!
Loss of efficiency!
• It is highly recommended that any dismantling of the machine that goes beyond any-
thing that is described in this manual should be done through Busch.
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
In case of the machine having conveyed gas that was contaminated with foreign materi-
als which are dangerous to health:
• Decontaminate the machine as well as possible and state the contamination status
in a ‘Declaration of Contamination’.
Busch will only accept machines that come with a completely filled in and legally binding
signed ‘Declaration of Contamination’.
(Form downloadable from
www.buschvacuum.com
)
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Turn off the cooling liquid supply.
• Vent the connected lines to atmospheric pressure.
• Disconnect all connections.
If the machine is going to be stored:
• See
Storage [
►
11]
.
9.1 Dismantling and Disposal
• Drain the oil.
• Drain the cooling liquid.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
Содержание COBRA ATEX
Страница 35: ...Note...