53

 of 175 

Slot 30, Index 41 to 58 

Slot 

Index  Description 

Value 

Meaning of value 

Type  Len  R/W 

30 

41 

Display the 

measurement menue,  

read the currently 

displayed measurement 

menue 

 

Note:

 The menue is 

selected here, but not 

yet displayed. Display 

only occurs through 

access to slot 30/115. 

101 

102 

103 

104 

105 

106 

107 

108 

 

109 

110 

111 

112 

113 

 

Y1 displaying meas. curves 

Y2 displaying meas. curves 

Y1 / Y2 displaying meas. curves 

General curve data Y1 

General curve data Y2 

Smiley, Pass/Fail display. 

Entry/Exit of window 

Entry/Exit of evaluation 

elements (except for window) 

User selected values 1 - 12 

User selected values 13 - 24 

Display statistics 

Order sheet 

Results of evaluation rotary 

switch 

U16 

RW 

30 

42 

Access authorisation 

Password protection 

on/off 

Password protection on 

Password protection off 

U16 

RW 

30 

43 

Access authorisation 

BASIC SETUP MENUE

 

Access level disabled 

Access level enabled 

U16 

RW 

30 

44 

Access authorisation 

MIN. SETUP MENUE 

Access level disabled 

Access level enabled 

U16 

RW 

30 

45 

Access authorisation 

MAIN SETUP MENUE 

Access level disabled 

Access level enabled 

U16 

RW 

30 

46 

Access authorisation 

CHANNEL SETUP 

MENUE 

Access level disabled 

Access level enabled 

U16 

RW 

30 

47 

Access authorisation  

MEASUREMENT 

MODE 

Access level disabled 

Access level enabled 

U16 

RW 

30 

48 

Access authorisation 

EVALUATION 

Access level disabled 

Access level enabled 

U16 

RW 

30 

49 

Access authorisation 

SWITCHPOINTS 

Access level disabled 

Access level enabled 

U16 

RW 

30 

50 

Access authorisation 

TEST OPERATION 

SIMPLE 

Access level disabled 

Access level enabled 

U16 

RW 

30 

51 

Access authorisation 

TEST OPERATION 

COMPLEX 

Access level disabled 

Access level enabled 

U16 

RW 

30 

52 

Access authorisation 

SENSOR TEST 

Access level disabled 

Access level enabled 

U16 

RW 

Содержание DIGIFORCE 9307

Страница 1: ...l rights reserved Talstra e 1 5 76593 Gernsbach Germany Postbox 1432 76587 Gernsbach Germany Valid from 30 07 2015 Applies to DIGIFORCE 9307 Vxxx2 Tel 49 07224 6450 Fax 49 07224 64588 E Mail info burs...

Страница 2: ...onsmesstechnik hereinafter referred to as product are the results of targeted development and meticulous research As of the date of delivery burster provides a warranty for the proper condition and fu...

Страница 3: ...ce immunity 14 3 4 2 Emitted interference 14 3 5 Notes on CE labeling 14 4 Installation 15 4 1 Connection of fieldbus lines 15 4 2 Installation of fieldbus lines 15 4 2 1 Parameter value 16 4 2 2 Tran...

Страница 4: ...ault assignment of output Byte 4 2 adjustable outputs 27 6 4 Evaluation info 28 6 4 1 Evaluation info Byte 1 28 6 4 2 Evaluation info Byte 2 29 6 4 3 Evaluation info Byte 3 29 6 4 4 Evaluation info By...

Страница 5: ...Slot 48 92 7 4 20 Evaluation window 5 Slot 49 92 7 4 21 Evaluation window 6 Slot 50 93 7 4 22 Evaluation window 7 Slot 51 93 7 4 23 Evaluation window 8 Slot 52 93 7 4 24 Evaluation window 9 Slot 53 93...

Страница 6: ...w 1 EvElem 1 129 7 5 8 Statistic measurement result evaluation element window 2 EvElem2 129 7 5 9 Statistic measurement result evaluation element window 3 EvElem3 129 7 5 10 Statistic measurement resu...

Страница 7: ...measurement result evaluation element mathematical calculation 5 EvElem25 131 7 5 32 Statistic measurement result evaluation element mathematical calculation 6 EvElem26 131 7 5 33 Read out X coordinat...

Страница 8: ...5 56 Evaluation results trapezoid window Y 2 141 7 5 57 Evaluation results envelope 1 142 7 5 58 Evaluation results envelope 2 142 7 5 59 Evalutation results rotary switch evaluation elment 1 142 7 5...

Страница 9: ...n Symbols on the device Notice text on the device Read and observe the text beside below the alert symbol To prevent electrical shock do not open device To prevent fire replace only with same type and...

Страница 10: ...ference potential to VP GSD Device description data PI PROFIBUS and PROFINET International user organization RTS Request To Send RxD TxD N Receive Transmit Data N A line RxD TxD P Receive Transmit Dat...

Страница 11: ...fety and accident prevention regulations when commissioning the equipment Install automation engineering equipment and installations with sufficient protection against accidental actuation Warning con...

Страница 12: ...of displacement angle or time according to a defined curve The resultant measurement curve is analyzed using graphical evaluation elements such as windows envelopes and thresholds The result of the a...

Страница 13: ...bout PROFIBUS DP at www profibus com 3 2 Model 9307 device data Supported transfer rates 9 6 kBit s 187 5 kBit s 3000 kBit s 19 2 kBit s 500 kBit s 6000 kBit s 93 75 kBit s 1500 kBit s 12 000 kBit s B...

Страница 14: ...EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 3 5 Notes on CE labeling burster equipment carrying the CE mark meets the requirements of the EU directives and the harmonized European standards EN cited...

Страница 15: ...option have a 9 pin SUB D female connector for the fieldbus connection PIN Meaning 1 Shield 2 NC 3 RxD TxD P 4 NC 5 DGND 6 VP 5 V bus termination 7 NC 8 RxD TxD N 9 NC 4 2 Installation of fieldbus li...

Страница 16: ...ud 1000 m 500 kBaud 400 m 1500 kBaud 200 m 3000 6000 12000 kBaud 100 m Commercially available connectors allow the incoming data cable to be connected directly to the outgoing data cable in the connec...

Страница 17: ...IBUS cable in order to achieve high system immunity to radiated electromagnetic interference As far as possible the shield should be connected at both ends to the protective ground via large area shie...

Страница 18: ...r power on the measurement mode is always set The display will look differently dependent on your settings or your last measurements You can go to Main setup menue in measurement mode by pressing the...

Страница 19: ...ts on the PROFIBUS interface PLC DIGIFORCE 9307 responds solely to control signals inputs on the PLC I O interface When controlled via PLC I O data is still transferred in the cyclical PROFIBUS DP pro...

Страница 20: ...the measurement equipment They condition the input data from the measurement application for communication with the master and condition the output data control signals from the master for forwarding...

Страница 21: ...rement results per access which the master makes no use of On the other hand there are applications in which the measurement results from a specific evaluation element need to be transferred but this...

Страница 22: ...d with b or bin are binary numbers Example b1100 bin1100 1100b 1100bin 5 4 2 Handling problems that arise when reading floating point numbers This only concerns cases in which floating point numbers n...

Страница 23: ...selectable list M5 1 12x4 12 evaluation values float selectable list M5 2 12x4 6 evaluation values float selectable list curve 6x4 5 PLC output status 4 140 bytes Evaluation info 4 12 evaluation value...

Страница 24: ...GIFORCE 9307 are always transferred from the PROFIBUS master to the DIGIFORCE 9307 These bits have the same function as the parallel PLC inputs to the DIGIFORCE 9307 unit See detailed documentation of...

Страница 25: ...8 measurement programs If not used set this bits to 0 6 2 4 PLC inputs Byte 4 master to slave PLC inputs Byte 4 Master Slave Valid values IN_START Bit 0 LSB reserved Bit 1 Set reserved bits to 0 reser...

Страница 26: ...RCE 9307 operation manual for the unit Also the signal timing is available within the DIGIFORCE 9307 operation manual 6 3 1 PLC outputs Byte 1 PLC outputs Byte 1 Slave Master Valid values OUT_READY Bi...

Страница 27: ...1 PLC_OUT22 Bit 2 PLC_OUT21 Bit 3 PLC_OUT20 Bit 4 PLC_OUT19 Bit 5 PLC_OUT18 Bit 6 PLC_OUT17 Bit 7 MSB NOTE Note that PLC outputs PLC_OUT 23 1 could be assigned with different functions The assignment...

Страница 28: ...C_OUT20 OUT_WARNING_TOOLCOUNT PLC_OUT21 OUT_WARNING_TOTAL PLC_OUT22 OUT_TEST_OP_SIMPLE PLC_OUT23 OUT_TEST_OP_COMPLEX 6 4 Evaluation info The evaluation info 4 byte contains the evaluation result of ea...

Страница 29: ...3 Evaluation info Byte 3 Evaluation info Byte 3 Slave Master Valid values Window_9_NOK Bit 0 LSB Window_10_NOK Bit 1 Trapezoid_X1_NOK Bit 2 Trapezoid_X2_NOK Bit 3 Trapezoid_Y1_NOK Bit 4 Trapezoid_Y2_...

Страница 30: ...2 PLC outputs Byte 3 6 3 3 3 PLC outputs Byte 4 6 3 4 4 Evaluation info Byte 1 6 4 1 5 Evaluation info Byte 2 6 4 2 6 Evaluation info Byte 3 6 4 3 7 Evaluation info Byte 4 6 4 4 6 5 2 Mode 2 Data fro...

Страница 31: ...5 1 value_3 2nd Byte see above 18 M5 1 value_3 3rd Byte see above 19 M5 1 value_3 4th Byte see above 20 M5 1 value_4 1st Byte see above User defined value in DIGIFORCE 9307 List M5 1 32 Bit float 21 M...

Страница 32: ...List M5 1 32 Bit float 45 M5 1 value_10 2nd Byte see above 46 M5 1 value_10 3rd Byte see above 47 M5 1 value_10 4th Byte see above 48 M5 1 value_11 1st Byte see above User defined value in DIGIFORCE 9...

Страница 33: ...Byte see above 14 M5 1 value_2 3rd Byte see above 15 M5 1 value_2 4th Byte see above 16 M5 1 value_3 1st Byte see above User defined value in DIGIFORCE 9307 List M5 1 32 Bit float 17 M5 1 value_3 2nd...

Страница 34: ...45 M5 1 value_10 2nd Byte see above 46 M5 1 value_10 3rd Byte see above 47 M5 1 value_10 4th Byte see above 48 M5 1 value_11 1st Byte see above User defined value in DIGIFORCE 9307 List M5 1 32 Bit f...

Страница 35: ...above 80 M5 2 value_7 1st Byte see above User defined value in DIGIFORCE 9307 List M5 2 32 Bit float 81 M5 2 value_7 2nd Byte see above 82 M5 2 value_7 3rd Byte see above 83 M5 2 value_7 4th Byte see...

Страница 36: ...uts Byte 1 6 3 1 1 PLC outputs Byte 2 6 3 2 2 PLC outputs Byte 3 6 3 3 3 PLC outputs Byte 4 6 3 4 4 Evaluation info Byte 1 6 4 1 5 Evaluation info Byte 2 6 4 2 6 Evaluation info Byte 3 6 4 3 7 Evaluat...

Страница 37: ...see above 32 M5 1 value_7 1 st Byte see above User defined value in DIGIFORCE 9307 List M5 1 32 Bit float 33 M5 1 value_7 2 nd Byte see above 34 M5 1 value_7 3 rd Byte see above 35 M5 1 value_7 4 th B...

Страница 38: ...Bit float 65 M5 2 value_3 2 nd Byte see above 66 M5 2 value_3 3 rd Byte see above 67 M5 2 value_3 4 th Byte see above 68 M5 2 value_4 1 st Byte see above User defined value in DIGIFORCE 9307 List M5 2...

Страница 39: ...above User defined value in DIGIFORCE 9307 List M5 2 32 Bit float 101 M5 2 value_12 2 nd Byte see above 102 M5 2 value_12 3 rd Byte see above 103 M5 2 value_12 4 th Byte see above 104 M1_Curvevalue_1...

Страница 40: ..._6 4 th Byte see above 6 5 5 Mode 5 Data from master to slave Byte Function Section Comments 0 PLC inputs Byte 1 6 2 1 1 PLC inputs Byte 2 6 2 2 2 PLC inputs Byte 3 6 2 3 3 PLC inputs Byte 4 6 2 4 Dat...

Страница 41: ...value_5 3 rd Byte see above 27 M5 1 value_5 4 th Byte see above 28 M5 1 value_6 1 st Byte see above User defined value in DIGIFORCE 9307 List M5 1 32 Bit float 29 M5 1 value_6 2 nd Byte see above 30...

Страница 42: ...bove User defined value in DIGIFORCE 9307 List M5 2 32 Bit float 61 M5 2 value_2 2 nd Byte see above 62 M5 2 value_2 3 rd Byte see above 63 M5 2 value_2 4 th Byte see above 64 M5 2 value_3 1 st Byte s...

Страница 43: ...M5 2 value_10 4 th Byte see above 96 M5 2 value_11 1 st Byte see above User defined value in DIGIFORCE 9307 List M5 2 32 Bit float 97 M5 2 value_11 2 nd Byte see above 98 M5 2 value_11 3 rd Byte see a...

Страница 44: ...ve User defined value in DIGIFORCE 9307 value in curve M1 32 Bit float 125 M1_Curvevalue_6 2 nd Byte see above 126 M1_Curvevalue_6 3 rd Byte see above 127 M1_Curvevalue_6 4 th Byte see above 128 Live...

Страница 45: ...e PROFIBUS masters however the slot is already addressed implicitly through the selected mode e g on the Siemens S7 The DIGIFORCE 9307 offers a solution for cases in which your PROFIBUS master cannot...

Страница 46: ...see 7 4 1 General settings Slot 30 As soon as the slot address has been successfully mapped in the DIGIFORCE 9307 the slot address that has been entered can be read at the index address type 100 ms N...

Страница 47: ...nate group 2 Measured value 400 599 etc 4 The number of the desired coordinate group is entered through a write access to index 19 Since we want to read the beginning of the curve we enter a 0 It is n...

Страница 48: ...19 It is now possible to write the curve values no 0 199 to indices 20 219 3 The coordinate group that is to be written to is selected e g 1 for values 200 399 through a write access to index 19 It i...

Страница 49: ...the number of the slot to be linked R Read the number of the currently linked slot no slot linked 0 U16 2 RW 0 29 2 9 Not possible X 0 29 10 240 Indices of the linked slots RW 7 4 Slot index tables c...

Страница 50: ...e XX 30 19 Station name Stat14 right STR 15 15 RW 30 20 Tool counter 0 4294967296 U32 4 RO Slot 30 Index 21 to 40 Slot Index Description Value Meaning of value Type Len R W 30 21 Standard value for to...

Страница 51: ...nction key definition F2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Off Meas menue page up Meas menue page down Meas program incremental Meas program decremental Tare X Tare Y Tare Y2 Measurement Start Stop Ackn...

Страница 52: ...bled Meas menue enabled U16 2 RW 30 34 Meas menue display control GENERAL CURVE DATA 0 1 Meas menue disabled Meas menue enabled U16 2 RW 30 35 Meas menue display control TOTAL Off Smiley text 0 1 Meas...

Страница 53: ...0 43 Access authorisation BASIC SETUP MENUE 0 1 Access level disabled Access level enabled U16 2 RW 30 44 Access authorisation MIN SETUP MENUE 0 1 Access level disabled Access level enabled U16 2 RW 3...

Страница 54: ...Strobe switch program U16 2 RW 30 59 PLC output 1 Pin 2 3 A0 switch program U16 2 RW 30 59 PLC output 1 Pin 2 4 A1 switch program U16 2 RW 30 59 PLC output 1 Pin 2 5 A2 switch program U16 2 RW 30 59...

Страница 55: ...in 2 33 NOK trapezoid window X 2 U16 2 RW 30 59 PLC output 1 Pin 2 34 NOK threshold 1 U16 2 RW 30 59 PLC output 1 Pin 2 35 NOK threshold 2 U16 2 RW 30 59 PLC output 1 Pin 2 36 NOK threshold 3 U16 2 RW...

Страница 56: ...11 see slot 59 U16 2 RW 30 65 PLC output 7 Pin 12 see slot 59 U16 2 RW 30 66 PLC output 8 Pin 13 see slot 59 U16 2 RW 30 67 PLC output 9 Pin 16 see slot 59 U16 2 RW 30 68 PLC output 10 Pin 17 see slot...

Страница 57: ...ftname_ Shift1 STR 64 64 RW 30 91 Order sheet Shift name Shift 2 Shiftname_ Shift2 STR 64 64 RW 30 92 Order sheet Shift name Shift 3 Shiftname_ Shift3 STR 64 64 RW 30 93 Order sheet Shift name Shift 4...

Страница 58: ...nter read out quantity of NOK counts shift 2 0 4294967296 U32 4 RO 30 107 Order sheet Shift counter read out quantity of NOK counts shift 3 0 4294967296 U32 4 RO 30 108 Order sheet Shift counter read...

Страница 59: ...of the LCD display EVENT Writing an arbitrary byte initiates action U8x 1 WO 32 12 Fault status of the internal serial communication 0x00000001 PREFIX addressing fault U32x 4 RO 32 12 Fault status of...

Страница 60: ...l serial communication 0x00004000 Reading out the measurement curve was interrupted by the beginning of a new measurement U32x 4 RO 32 12 Fault status of the internal serial communication 0x00008000 I...

Страница 61: ...signal C Incr TTL C Incr sinus 1Vpp C Incr sinus 11 uApp D strain gauge D Potentiometer D standard signal D Incr TTL E resistance F Piezo time reserved C SSI C EnDat U16 2 RW 34 11 Channel settings ch...

Страница 62: ...nce F Piezo Time off C SSI C EnDat U16 2 RW 34 13 Accept channel settings Event The settings from indices 10 11 12 are being stored Writing an arbitrary byte initiates action U8 1 WO 34 14 Filter chan...

Страница 63: ...Transmitter supply off Transmitter supply on U16 2 RW 34 18 Transmitter supply channel Y1 Note Entry is not available for the channel settings Piezo and Resistance 0 1 Transmitter supply off Transmit...

Страница 64: ...Y2 Note Entry is not available for the channel settings Off Time and Resistance 0 1 2 3 4 5 6 7 8 9 10 11 12 User defined unit 1 User defined unit 2 User defined unit 3 mm N kN Nm Ncm grd bar V s ms...

Страница 65: ...ental and Resistance EVENT FLT 4 RO 34 29 Channel to be scaled 0 1 2 Channel X Channel Y1 Channel Y2 U 16 2 WO 34 30 Lower scale value Concerns the channel selected under index 29 FLT 4 RW 34 31 Upper...

Страница 66: ...le X 36 1 9 Reserved X 36 10 Standard signal input channel X 0 1 5 V input range 10 V input range U16 2 RW 36 11 Standard signal input channel Y1 0 1 5 V input range 10 V input range U16 2 RW 36 12 St...

Страница 67: ...el Y2 0 1 2 3 4 5 1 mV V input range 2 mV V input range 4 mV V input range 10 mV V input range 20 mV V input range 40 mV V input range 40 mV V are not allowed at 10 V excitation U16 2 RW 37 16 Strain...

Страница 68: ...rved X 38 10 Resistance input range channel X 0 1 2 200 mOhm range 2 kOhm range 100 kOhm range U16 2 RW 38 11 Resistance input range channel Y1 0 1 2 200 mOhm range 2 kOhm range 100 kOhm range U16 2 R...

Страница 69: ...cuit piezo input Short circuit piezo input U16 2 RW 39 14 Piezo short circuit on to channel Y1 0 1 Do not short circuit piezo input Short circuit piezo input U16 2 RW 39 15 Piezo short circuit on to c...

Страница 70: ...rence measurement on off channel X 0 1 off on U16 2 RW 40 17 Incremental reference measurement on off channel Y1 0 1 off on U16 2 RW 40 18 Incremental reference measurement on off channel Y2 0 1 off o...

Страница 71: ...4 FLT 4 RW 40 30 Incremental grating period channel Y2 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 40 31 Incremental interpolation channel X between 1 and 65000 Int...

Страница 72: ...sensor Singleturn encoder Multiturn encoder U16 2 RW 41 12 SSI sensor type channel Y2 Note At the end settings must be initiated through a write access to indices 37 38 39 0 1 2 Displacement sensor S...

Страница 73: ...t aligned Tree U16 2 RW 41 18 SSI format channel Y2 Note Only permitted for multiturn angle sensor At the end settings must be initiated through a write access to indices 37 38 39 0 1 Right aligned Tr...

Страница 74: ...Hz 1 MHz U16 2 RW 41 25 SSI resolution channel X Note Only permitted for displacement sensors At the end settings must be initiated through a write access to indices 37 38 39 between 9999999 0 and 999...

Страница 75: ...d settings must be initiated through a write access to indices 37 38 39 0 48 Integer value U16 2 RW 41 31 SSI bit number angle singleturn or displacement channel X Note At the end settings must be ini...

Страница 76: ...rough a write access to indices 37 38 39 0 32 Integer value U16 2 RW 41 36 SSI bit number rotations for multiturn angle channel Y2 Note At the end settings must be initiated through a write access to...

Страница 77: ...itiated through a write access to index 17 EVENT Writing an arbitrary byte initiates action U8 1 WO 42 12 Read out EnDat sensor data channel Y2 Note At the end settings must be initiated through a wri...

Страница 78: ...ead beforehand and the clock frequency must be set EVENT Writing an arbitrary byte initiates action U8 1 WO 42 18 Copy EnDat sensor setup channel Y2 Note Sensor data must be read beforehand and the cl...

Страница 79: ...2 2 See comment at the end of the slot angle z axis STR20 20 RW 42 26 EnDat name of sensor channel Y1 Note Only available with EnDat 2 2 See comment at the end of the slot angle z axis STR20 20 RW 42...

Страница 80: ...turn encoder STR20 20 RW 42 33 EnDat sensor type channel Y2 Note See comment at the end of the slot 0 1 2 Displacement Singelturn encoder Multiturn encoder STR20 20 RW 42 34 EnDat total number of bits...

Страница 81: ...eger value U16 2 RW 42 41 EnDat bit number angle multiturn channel Y1 Note See comment at the end of the slot 0 32 Integer value U16 2 RW 42 42 EnDat bit number angle multiturn channel Y2 Note See com...

Страница 82: ...it Integer value U16 2 RW 42 49 EnDat unit of measuring length channel X Note See comment at the end of the slot 0 1 2 3 GP grating period um Micrometer mm Millimeter m Meter U16 2 RW 42 50 EnDat unit...

Страница 83: ...alue U16 2 RW 42 55 Transmit EnDat manual sensor setup channel X Note Sensor data must be entered beforehand into the indices 19 54 EVENT Writing an arbitrary byte initiates action U8 1 WO 42 56 Trans...

Страница 84: ...not appropriate for the sensor has been written the results of the sensor measurements can no longer be read correctly In cases of doubt the data should not be written here manually but should instead...

Страница 85: ...r tare channel Y2 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 43 16 Tare warning on off channel X 0 1 off on U16 2 RW 43 17 Tare warning on off channel Y1 0 1 off o...

Страница 86: ...cription Value Meaning of value Type Len R W 44 0 Not possible X 44 1 9 Reserved X 44 10 X sampling off on 0 1 off on U16 2 RW 44 11 X sample rate between 0 0 and 9999999 0 Float value Float according...

Страница 87: ...s off Y2 trigger underrun not allowed when channel Y2 is off 44 19 Set reference line Y1 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 44 20 Set reference line Y2 bet...

Страница 88: ...r internal start between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 44 29 Set Y1 start value for internal start between 9999999 0 and 9999999 0 Float value Float according...

Страница 89: ...t according to IEEE754 FLT 4 RW 45 12 Window 1 limit Xmax Note At the end entry must be adopted through index 15 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 45 13 W...

Страница 90: ...the end entry must be adopted through index 24 0 1 no yes U16 2 RW 45 21 Window 1 exit right Note At the end entry must be adopted through index 24 0 1 no yes U16 2 RW 45 22 Window 1 exit bottom Note...

Страница 91: ...Window 1 delta gradient for bend between 0 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 45 34 Window 1 delta Y for bend between 0 0 and 9999999 0 Float value Float according to IEEE...

Страница 92: ...ble X 46 1 9 Reserved X 46 10 See slot 45 7 4 18 Evaluation window 3 Slot 47 Slot Index Description Value Meaning of value Type Len R W 47 0 Not possible X 47 1 9 Reserved X 47 10 See slot 45 7 4 19 E...

Страница 93: ...Reserved X 51 10 See slot 45 7 4 23 Evaluation window 8 Slot 52 Slot Index Description Value Meaning of value Type Len R W 52 0 Not possible X 52 1 9 Reserved X 52 10 See slot 45 7 4 24 Evaluation win...

Страница 94: ...index 17 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 55 14 Trapezoid X1 Y limit top right Note At the end entry must be adopted through index 17 between 9999999 0...

Страница 95: ...5 21 Trapez X1 exit right Note At the end entry must be adopted through index 22 0 1 no yes U16 2 RW 55 22 Trapezoid X1 copy entry exit Note Values entered into indices 16 21 are adopted EVENT Writing...

Страница 96: ...Trapezoid Y1 limit Ymax Note At the end entry must be adopted through index 17 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 57 13 Trapezoid Y1 X limit top left Note...

Страница 97: ...Y1 entry bottom Note At the end entry must be adopted through index 22 0 1 no yes U16 2 RW 57 19 Trapezoid Y1 entry top Note At the end entry must be adopted through index 22 0 1 no yes U16 2 RW 57 2...

Страница 98: ...X 58 1 9 Reserved X 58 10 See slot 57 7 4 30 Evaluation threshold 1 Slot 59 Slot Index Description Value Meaning of value Type Len R W 59 0 Not possible X 59 1 9 Reserved X 59 10 Threshold 1 off on 0...

Страница 99: ...the end entry must be adopted through index 18 0 1 no yes U16 2 RW 59 17 Threshold 1 passage Type X right left Type Y top bottom Note At the end entry must be adopted through index 18 0 1 no yes U16...

Страница 100: ...mum Note Only for type Y 0 1 no yes U16 2 RW 59 27 Threshold 1 Calculate absolute minimum Note Only for type Y 0 1 no yes U16 2 RW 59 28 Threshold 1 Calculate local maximum Note Only for type Y 0 1 no...

Страница 101: ...en R W 60 0 Not possible X 60 1 9 Reserved X 60 10 See slot 59 7 4 32 Evaluation threshold 3 Slot 61 Slot Index Description Value Meaning of value Type Len R W 61 0 Not possible X 61 1 9 Reserved X 61...

Страница 102: ...ding to IEEE754 FLT 4 RW 75 13 Math function Constant 4 between 9999999 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 75 14 Math function Constant 5 between 9999999 0 and 9999999 0 F...

Страница 103: ...index 23 Integer value See operand table in appendix U16 2 RW 75 23 Math function Copy formula 1 Note Values entered into indices 20 22 are adopted EVENT Writing an arbitrary byte initiates action U8...

Страница 104: ...index 31 0 1 2 3 Sum up Subtract Multiply Divide U16 2 RW 75 30 Math function formula row 3 operand B Note At the end entry must be adopted through index 31 Integer value See operand table in appendi...

Страница 105: ...ndex 39 Integer value See operand table in appendix U16 2 RW 75 37 Math function formula row 5 operator Note At the end entry must be adopted through index 39 0 1 2 3 Sum up Subtract Multiply Divide U...

Страница 106: ...d EVENT Writing an arbitrary byte initiates action U8 1 WO 75 44 Math function formula row 7 operand A Note At the end entry must be adopted through index 47 Integer value See operand table in appendi...

Страница 107: ...index 51 Integer value See operand table in appendix U16 2 RW 75 51 Math function Copy formula 8 Note Values entered into indices 48 50 are adopted EVENT Writing an arbitrary byte initiates action U8...

Страница 108: ...p Subtract Multiply Divide U16 2 RW 75 58 Math function formula row 10 operand B Note At the end entry must be adopted through index 59 Integer value See operand table in appendix U16 2 RW 75 59 Math...

Страница 109: ...operand table in appendix U16 2 RW 75 65 Math function Evaluation operand 2 Min tolerance limit Note At the end entry must be adopted through index 67 between 9999999 0 and 9999999 0 Float value Floa...

Страница 110: ...ed EVENT Writing an arbitrary byte initiates action U8 1 WO 75 72 Math function Evaluation operand 4 Note At the end entry must be adopted through index 75 Integer value See operand table in appendix...

Страница 111: ...and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 75 79 Math function Copy evaluation 5 Note Values entered into indices 76 78 are adopted EVENT Writing an arbitrary byte initiates action...

Страница 112: ...ance band Y1 Note At the end entry must be adopted through index 13 between 0 0 and 9999999 0 Float value Float according to IEEE754 FLT 4 RW 76 12 Tolerance band Y2 Note At the end entry must be adop...

Страница 113: ...At the end entry must be adopted through index 14 0 1 Absolute reference Trigger reference U16 2 RW 77 14 Switchpoint 1 Copy settings Note Values entered into indices 10 13 are adopted EVENT Writing...

Страница 114: ...initiates action U8 1 WO 81 14 Sensor test Channel Y1 measure reference value EVENT Writing an arbitrary byte initiates action U8 1 WO 81 15 Sensor test Channel Y2 measure reference value EVENT Writi...

Страница 115: ...Type Len R W 82 0 Not possible X 82 1 9 Reserved X 82 10 User defined values value 1 Integer value See operand table in appendix U16 2 RW 82 11 User defined values value 2 Integer value See operand ta...

Страница 116: ...teger value See operand table in appendix U16 2 RW 82 27 User defined values value 18 Integer value See operand table in appendix U16 2 RW 82 28 User defined values value 19 Integer value See operand...

Страница 117: ...ettings from indices 10 12 are being adopted through indices 13 14 or 15 0 31 0 127 In the standard device In the corresponding device version U16 2 WO 83 11 Meas program number Target start Note The...

Страница 118: ...t value channel X Float value Float according to IEEE754 FLT 4 RO 89 11 Current measurement value channel Y Float value Float according to IEEE754 FLT 4 RO 89 12 Current measurement value channel Y Fl...

Страница 119: ...90 16 Fix scale Xmin channel Y2 Note At the end entry must be adopted through index 20 Float value Float according to IEEE754 FLT 4 RW 90 17 Fix scale Xmax channel Y2 Note At the end entry must be ado...

Страница 120: ...t Integer value 0 means that there is no measurement curve U16 2 RO 100 11 Running measurement curve counter 32 Bit Integer value This counter is incremented by 1 when a measurement curve is newly acq...

Страница 121: ...f the A D converter 0 1 No overdrive Overdrive U16 2 RO 101 18 Date of recording String in format dd mm yyyy STR10 10 RO 101 19 Time of recording hh mm ss String in format hh mm ss STR8 8 RO 101 20 Un...

Страница 122: ...Float value Float according to IEEE754 FLT 4 RO 103 14 Y1 minimum X coordinate Float value Float according to IEEE754 FLT 4 RO 103 15 Y1 minimum Y1 coordinate Float value Float according to IEEE754 F...

Страница 123: ...ue 2 name String with the designator of the value Designator 0 means that no value is defined for this value number STR16 16 RO 105 14 User defined value 2 measurement value Float value Float accordin...

Страница 124: ...h STR4 4 RO 105 28 User defined value 7 name String with the designator of the value Designator 0 means that no value is defined for this value number STR16 16 RO 105 29 User defined value 7 measureme...

Страница 125: ...s defined for this value number STR16 16 RO 105 44 User defined value 12 measurement value Float value Float according to IEEE754 FLT 4 RO 105 45 User defined value 12 unit String with max 4 character...

Страница 126: ...EE754 FLT 4 RO 105 60 User defined value 17 unit String with max 4 characters e g N or inch STR4 4 RO 105 61 User defined value 18 name String with the designator of the value Designator 0 means that...

Страница 127: ...STR4 4 RO 105 76 User defined value 23 name String with the designator of the value Designator 0 means that no value is defined for this value number STR16 16 RO 105 77 User defined value 23 measurem...

Страница 128: ...e String with the designator of the value Designator 0 means that no value is defined for this value number STR16 16 RO 105 92 User defined value 28 measurement value Float value Float according to IE...

Страница 129: ...element window 5 EvElem5 Slot index data on request 7 5 12 Statistic measurement result evaluation element window 6 EvElem6 Slot index data on request 7 5 13 Statistic measurement result evaluation el...

Страница 130: ...window X1 EvElem15 Slot index data on request 7 5 22 Statistic measurement result evaluation element trapezoid window X2 EvElem16 Slot index data on request 7 5 23 Statistic measurement result evalua...

Страница 131: ...tic measurement result evaluation element mathematical calculation 3 EvElem23 Slot index data on request 7 5 30 Statistic measurement result evaluation element mathematical calculation 4 EvElem24 Slot...

Страница 132: ...ates For example if coordinates 600 799 are to be displayed there must be a 3 here Query the maximum number of value pairs under slot 132 10 Read access Group of 200 coordinates currently displayed In...

Страница 133: ...7 5 35 Read out Y2 coordinates of current measurement curve Slot Index Description Value Meaning of value Type Len R W 134 0 Not possible X X 134 1 9 Reserved X X 134 10 See slot 132 X X 7 5 36 Read o...

Страница 134: ...s Float value Float according to IEEE754 FLT 4 RO 135 22 2 coordinate of group of coordinates Float value Float according to IEEE754 FLT 4 RO 135 23 3 coordinate of group of coordinates Float value Fl...

Страница 135: ...rve Y coordinate Float value Float according to IEEE754 FLT 4 RO 138 14 Window 1 exit of curve X coordinate Float value Float according to IEEE754 FLT 4 RO 138 15 Window 1 exit of curve Y coordinate F...

Страница 136: ...FLT 4 RO 138 26 Window 1 gradient value Float value Float according to IEEE754 FLT 4 RO 138 27 Window 1 Y mean value Float value Float according to IEEE754 FLT 4 RO 138 28 Window 1 area below curve F...

Страница 137: ...Value Meaning of value Type Len R W 144 0 Not possible X X 144 1 9 Reserved X X 144 10 See slot 138 X X 7 5 46 Evaluation results window 8 Slot Index Description Value Meaning of value Type Len R W 1...

Страница 138: ...4 RO 148 14 Threshold 1 absolute Y maximum in threshold X coordinate Float value Float according to IEEE754 FLT 4 RO 148 15 Threshold 1 absolute Y maximum in threshold Y coordinate Float value Float a...

Страница 139: ...lue Float according to IEEE754 FLT 4 RO 148 25 Threshold 1 Y mean value Float value Float according to IEEE754 FLT 4 RO 148 26 Threshold 1 area below curve Float value Float according to IEEE754 FLT 4...

Страница 140: ...o IEEE754 FLT 4 RO 152 14 Trapezoid X 1 exit coordinate X coordinate Float value Float according to IEEE754 FLT 4 RO 152 15 Trapezoid X 1 exit coordinate Y coordinate Float value Float according to IE...

Страница 141: ...Float value Float according to IEEE754 FLT 4 RO 154 14 Trapezoid Y 1 exit coordinate X coordinate Float value Float according to IEEE754 FLT 4 RO 154 15 Trapezoid Y 1 exit coordinate Y coordinate Flo...

Страница 142: ...O 156 14 Envelope 1 exit coordinate X coordinate Float value Float according to IEEE754 FLT 4 RO 156 15 Envelope 1 exit coordinate Y coordinate Float value Float according to IEEE754 FLT 4 RO 7 5 58 E...

Страница 143: ...EEE754 FLT 4 RO 158 18 Rotary switch evaluation element 1 X coord minima 2 Float value Float according to IEEE754 FLT 4 RO 158 19 Rotary switch evaluation element 1 X coord minima 3 Float value Float...

Страница 144: ...ording to IEEE754 FLT 4 RO 158 32 Rotary switch evaluation element 1 X coord minima 16 Float value Float according to IEEE754 FLT 4 RO 158 33 Rotary switch evaluation element 1 X coord minima 17 Float...

Страница 145: ...ccording to IEEE754 FLT 4 RO 158 46 Rotary switch evaluation element 1 X coord minima 30 Float value Float according to IEEE754 FLT 4 RO 158 47 Rotary switch evaluation element 1 X coord minima 31 Flo...

Страница 146: ...ding to IEEE754 FLT 4 RO 158 60 Rotary switch evaluation element 1 Y coord minima 12 Float value Float according to IEEE754 FLT 4 RO 158 61 Rotary switch evaluation element 1 Y coord minima 13 Float v...

Страница 147: ...ording to IEEE754 FLT 4 RO 158 74 Rotary switch evaluation element 1 Y coord minima 26 Float value Float according to IEEE754 FLT 4 RO 158 75 Rotary switch evaluation element 1 Y coord minima 27 Float...

Страница 148: ...ding to IEEE754 FLT 4 RO 158 88 Rotary switch evaluation element 1 X coord maxima 8 Float value Float according to IEEE754 FLT 4 RO 158 89 Rotary switch evaluation element 1 X coord maxima 9 Float val...

Страница 149: ...ing to IEEE754 FLT 4 RO 158 102 Rotary switch evaluation element 1 X coord maxima 22 Float value Float according to IEEE754 FLT 4 RO 158 103 Rotary switch evaluation element 1 X coord maxima 23 Float...

Страница 150: ...ording to IEEE754 FLT 4 RO 158 116 Rotary switch evaluation element 1 Y coord maxima 4 Float value Float according to IEEE754 FLT 4 RO 158 117 Rotary switch evaluation element 1 Y coord maxima 5 Float...

Страница 151: ...rding to IEEE754 FLT 4 RO 158 130 Rotary switch evaluation element 1 Y coord maxima 18 Float value Float according to IEEE754 FLT 4 RO 158 131 Rotary switch evaluation element 1 Y coord maxima 19 Floa...

Страница 152: ...rd maxima 30 Float value Float according to IEEE754 FLT 4 RO 158 143 Rotary switch evaluation element 1 Y coord maxima 31 Float value Float according to IEEE754 FLT 4 RO 158 144 Rotary switch evaluati...

Страница 153: ...nctions evaluation result line 6 0 1 NOK OK U16 2 RO 160 16 Math functions NOK counter line 1 32bit Integer value 0 U32 4 RO 160 17 Math functions NOK counter line 2 32bit Integer value 0 U32 4 RO 160...

Страница 154: ...transmitted as STRUCT X minimum X coordinate X minimum Y1 coordinate X maximum X coordinate X maximum Y1 coordinate Y1 minimum X coordinate Y1 minimum Y1 coordinate Y1 maximum X coordinate Y1 maximum...

Страница 155: ...n Y coordinate Bending point X coordinate Bending point Y coordinate Mean value Y Gradient Area Window Xmin coordinate Window Xmax coordinate Window Ymin coordinate Window Ymax coordinate STRUCT 88 RO...

Страница 156: ...e Absolute Ymax X coordinate Absolute Ymax Y coordinate Absolute Ymin X coordinate Absolute Ymin Y coordinate Local Ymax X coordinate Local Ymax Y coordinate Local Ymin X coordinate Local Ymin Y coord...

Страница 157: ...dinate Local Ymax X coordinate Local Ymax Y coordinate Local Ymin X coordinate Local Ymin Y coordinate Bending point X coordinate Bending point Y coordinate Mean value Y Gradient Area Window Xmin coor...

Страница 158: ...dinate Local Ymax X coordinate Local Ymax Y coordinate Local Ymin X coordinate Local Ymin Y coordinate Bending point X coordinate Bending point Y coordinate Mean value Y Gradient Area Window Xmin coor...

Страница 159: ...ute Ymin X coordinate Absolute Ymin Y coordinate Local Ymax X coordinate Local Ymax Y coordinate Local Ymin X coordinate Local Ymin Y coordinate Bending point X coordinate Bending point Y coordinate M...

Страница 160: ...ermediate Result 3 103 Intermediate Result 4 104 Intermediate Result 5 105 Intermediate Result 6 106 Intermediate Result 7 107 Intermediate Result 8 108 Intermediate Result 9 109 Intermediate Result 1...

Страница 161: ...data Y1 Abs Ymax Y coordinate 310 General curve data Y1 Abs Ymin X coordinate 311 General curve data Y1 Abs Ymin Y coordinate 312 General curve data Y1 Return point X coordinate 313 General curve data...

Страница 162: ...14 Reference point 500 Window 1 Entry X 501 Window 1 Entry Y 502 Window 1 Exit X 503 Window 1 Exit Y 504 Window 1 Abs minimum X 505 Window 1 Abs minimum Y 506 Window 1 Abs maximum X 507 Window 1 Abs m...

Страница 163: ...minimum Y 606 Window 2 Abs maximum X 607 Window 2 Abs maximum Y 608 Window 2 Loc minimum X 609 Window 2 Loc minimum Y 610 Window 2 Loc maximum X 611 Window 2 Loc maximum Y 612 Window 2 Bend X 613 Wind...

Страница 164: ...nimum X 709 Window 3 Loc maximum Y 710 Window 3 Loc maximum X 711 Window 3 Loc maximum Y 712 Window 3 Bend X 713 Window 3 Bend Y 714 Window 3 Mean value Y 715 Window 3 Gradient 716 Window 3 Area 717 W...

Страница 165: ...w 4 Bend X 813 Window 4 Bend Y 814 Window 4 Mean value Y 815 Window 4 Gradient 816 Window 4 Area 817 Window 4 Coordinate Xmin 818 Window 4 Coordinate Xmax 819 Window 4 Coordinate Ymin 820 Window 4 Coo...

Страница 166: ...oordinate Xmin 918 Window 5 Coordinate Xmax 919 Window 5 Coordinate Ymin 920 Window 5 Coordinate Ymax 1000 Window 6 Entry X 1001 Window 6 Entry Y 1002 Window 6 Exit X 1003 Window 6 Exit Y 1004 Window...

Страница 167: ...nate Ymax 1100 Window 7 Entry X 1101 Window 7 Entry Y 1102 Window 7 Exit X 1103 Window 7 Exit Y 1104 Window 7 Abs minimum X 1105 Window 7 Abs minimum Y 1106 Window 7 Abs maximum X 1107 Window 7 Abs ma...

Страница 168: ...ow 8 Abs minimum X 1205 Window 8 Abs minimum Y 1206 Window 8 Abs maximum X 1207 Window 8 Abs maximum Y 1208 Window 8 Loc minimum X 1209 Window 8 Loc minimum Y 1210 Window 8 Loc maximum X 1211 Window 8...

Страница 169: ...aximum Y 1308 Window 9 Loc minimum X 1309 Window 9 Loc minimum Y 1310 Window 9 Loc maximum X 1311 Window 9 Loc maximum Y 1312 Window 9 Bend X 1313 Window 9 Bend Y 1314 Window 9 Mean value Y 1315 Windo...

Страница 170: ...indow 10 Bend X 1413 Window 10 Bend Y 1414 Window 10 Mean value Y 1415 Window 10 Gradient 1416 Window 10 Area 1417 Window 10 Coordinate Xmin 1418 Window 10 Coordinate Xmax 1419 Window 10 Coordinate Ym...

Страница 171: ...1606 Trapezoid window X2 Coordinate Ymin left 1607 Trapezoid window X2 Coordinate Ymin right 1608 Trapezoid window X2 Coordinate Ymax left 1609 Trapezoid window X2 Coordinate Ymax right 1700 Trapezoid...

Страница 172: ...e Xmin top 1808 Trapezoid window Y2 Coordinate Xmax bottom 1809 Trapezoid window Y2 Coordinate Xmax top 1900 Threshold 1 Pass X 1901 Threshold 1 Pass Y 1902 Threshold 1 Abs minimum X 1903 Threshold 1...

Страница 173: ...mum X 2005 Threshold 2 Abs maximum Y 2006 Threshold 2 Loc minimum X 2007 Threshold 2 Loc minimum Y 2008 Threshold 2 Loc maximum X 2009 Threshold 2 Loc maximum Y 2010 Threshold 2 Bend X 2011 Threshold...

Страница 174: ...3 Bend Y 2112 Threshold 3 Mean value Y 2113 Threshold 3 Gradient 2114 Threshold 3 Area 2115 Threshold 3 Coordinate X value 2116 Threshold 3 Coordinate Ymin 2117 Threshold 3 Coordinate Ymax 2200 Thres...

Страница 175: ...e 2216 Threshold 4 Coordinate Ymin 2217 Threshold 4 Coordinate Ymax 2300 Envelope 1 Entry X 2301 Envelope 1 Entry Y 2302 Envelope 1 Exit X 2303 Envelope 1 Exit Y 2304 Envelope 1 Coordinate Start X 230...

Отзывы: