121
of 175
Slot
Index Description
Value
Meaning of value
Type
Len R/W
101
14
Evaluation channel Y2
0
1
NOK
OK
U16
2
RO
101
15
Index of the curve´s
return point
Caution
: The number of
the pair of values is
shown on the display.
The index begins at 0,
the number at 1!
16 Bit Integer
value
U16
2
RO
101
16
Index of the last
measured value of the
curve
Caution
: The number of
the pair of values is
shown on the display.
The index begins at 0,
the number at 1!
16 Bit Integer
value
U16
2
RO
101
17
Status overdrive of the
A/D converter
0
1
No overdrive
Overdrive
U16
2
RO
101
18
Date of recording
String in format
dd.mm.yyyy
STR10 10
RO
101
19
Time of recording
hh:mm:ss
String in format
hh:mm:ss
STR8
8
RO
101
20
Unit channel X
String with max.
4 characters,
e.g. "N" or "inch"
STR4
4
RO
101
21
Unit channel Y1
String with max.
4 characters,
e.g. "N" or "inch"
STR4
4
RO
101
22
Unit channel Y2
String with max.
4 characters,
e.g. "N" or "inch"
STR4
4
RO
7.5.3 Further informationen for current pretrigger curve
Slot
Index Description
Value
Meaning of value
Type
Len R/W
102
0
Not possible
-
-
X
X
102
1…9 Reserved
-
-
X
X
102
10
Pretrigger recording
on/off
0
1
off
on
U16
2
RO
102
11
Whole amount of
pretrigger values
32 Bit Integer
value
U32
4
RO