Fixing - 

The appliance should be secured to the wall using the fixing brackets on the flange of the 

appliance. If it is to be mounted above the ground, care should be taken to ensure the wall is able 
to  take  the  weight  of  the  appliance  and  that  the  fixings  are  of  the  correct  type.  Use  all  6  screw 
holes in the brackets to attach to the wall. 
 
If  the  appliance  is  hearth  mounted  the 
fixing  is  intended  to  prevent  the 
appliance from  moving / toppling and it 
is  permissible  just  to  use  2  holes  in  the 
wall  brackets  or  to  drill  through  the 
appliance base and screw it to the floor. 
Alternatively, 

hearth 

mounted 

appliances  can  use  the  cable  fixing 
method by fixing eyebolts to the wall or 
fireplace  behind  and  pulling  it  back  into 
place. See diagram 
Do not fix the appliance directly to plasterboard as prolonged exposure to heat could affect it or 
the vapour layer behind. A layer of heat resistant board should be screwed to the wall instead. 
Fully purge pipes of air and any debris and connect the gas supply to the 8mm elbow on the fire. 
Leak test the supply using an approved method. Note: An isolating valve must be situated near the 
appliance for servicing. 
 
Site the thermostat at a suitable position where it will sense the room temperature.  
 
The  case  can  be  test  fitted  to  the  chassis  to  ensure  clearance.  The  gap  in  the  case  top  between 
grille and spacer slides over the top flange on the appliance. The bottom of the case has folded out 
brackets that slide over cut outs in the appliance chassis. 
 
The door on the appliance is secured with a magnet and it may be necessary to adjust the strength 
of the magnets grip. This can be done by bending the magnet holding bracket in or out to adjust. 
 
Remove case and place to one side. 
 
 

 

6.0 CLEARANCES TO COMBUSTIBLE MATERIALS AND SHELVES (See also 3.6) 

 

A  non  combustible  shelf  may  be  fitted  to  within  100mm  of  the  top  edge  of  the  fire frame.  Note 
that shelves  will get  hot and  delicate  ornaments,  wax candles etc should be kept away from hot 
surfaces. 
The wood of the fire surrounds may be fitted to within 100mm of the sides of the firebox provided 
it protrudes no further forward than 100mm.  

Any combustible side walls must be at least 500mm from the fire bed. 

Maximum depth of shelf 

 

100mm 

 

150mm 

 

200mm 

Minimum distance from  

 

250mm 

 

300mm 

 

350mm 

top of frame to underside of shelf . 

As  with  all  heaters  the  possibility  of  convection  staining  on  surfaces  in  the  vicinity  of  the  heater 
shall  be  considered  and  the  user  advised.  Particular  attention  should  taken  to  ensure  soft 
furnishings such as scatter rugs and curtains are kept at least 1 metre from the appliance.  

 
 

View of Cable end 

Screw 

Cable 

Fixing Cable 

Spacer 
Bracke

Eyebolt 

Содержание G4237 IMAGE

Страница 1: ...Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4237 8InstUser G20 31 Issue March09 v 3 TO OBTAIN YOUR FIRST YE...

Страница 2: ...lbow 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and also with just the Burley heater operating If outside of this tolerance the fault...

Страница 3: ...lled in high rise blocks of flats bed sitting rooms basements which are not open on at least one side bathrooms or bedrooms in corridors stairways landing or hallways of multi occupancy dwellings gara...

Страница 4: ...the top surface standing a minimum of 50mm above surrounding floor level or surrounded by a raised fixed fender of 50mm high The hearth must extend a minimum of 100mm in front of the fire bed and 50m...

Страница 5: ...s are of the correct type Use all 6 screw holes in the brackets to attach to the wall If the appliance is hearth mounted the fixing is intended to prevent the appliance from moving toppling and it is...

Страница 6: ...they have a minimum heat rating of 150o c Consideration should be given to the effect of expansion and contraction caused by temperature and back panels should be allowed to float or attached with a...

Страница 7: ...erature The case can be test fitted to the chassis to ensure clearance The gap in the case top between grille and spacer slides over the top flange on the appliance The bottom of the case has folded o...

Страница 8: ...ry pack and also explain that the batteries are not covered by warranty A handheld remote control is included in the box and this has a 9 volt battery to power it The battery should be changed annuall...

Страница 9: ...the main burner will not light check the thermostat position and if necessary select a warmer setting 9 2 To light the fire first ensure the red knob is turned clockwise to OFF Press the left hand red...

Страница 10: ...tally friendly manner Replacement rechargeable batteries for the fire and replacement handsets are available from Burley Appliances on 01572 756956 or through your retailer The 9 volt handset battery...

Страница 11: ...ormance and could lead to a hazard 10 4 FIREFRONTS The design of these affects combustion therefore only the correct front supplied with the appliance may be fitted 10 5 FIREGUARDS A fireguard is not...

Страница 12: ...t to the gas supply Test all joints for leaks Following the manufacturer s instructions re lay the fuel bed and replace the glass Light the fire using the method in the instructions and ensure that th...

Страница 13: ...athrooms bedrooms in corridors stairways landings or hallways of multi occupancy dwellings in garages or rooms containing petroleum products The guard on the appliance is to prevent risk of fire or in...

Страница 14: ...eater in which case they will select a flame height on the red knob then set the thermostat black knob to a comfort level In both cases if the room gets too hot the thermostat will automatically reduc...

Страница 15: ...about 20 seconds and then it will light the burner on high flame 6 To alternate between high and low flame use the flame buttons on the right hand side of the handset 7 To turn the fire OFF press the...

Страница 16: ...appliances to produce an initial odour after start up If the pilot flame should ever extinguish of its own accord ventilate the room and allow a minimum of 5 minutes before relighting Never attempt t...

Страница 17: ...67 and the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at...

Страница 18: ...sult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filte...

Страница 19: ...is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertai...

Страница 20: ...the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe re...

Отзывы: