background image

 

- 16 - 

around the burner area and fuel effects with a HEPA filtered vacuum with brush attachment. Using 
the relevant section from the installers manual refit the fuel effects, glass and case. 

On no account should the fire be used with glass removed. The fuel effects must not be replaced 
in a different position from the instructions, if they are broken replace immediately. Do not use 
additional or non standard fuel effects as to do so could cause a hazard. 

If the fire is equipped with a remote control then check and change the batteries as described in 
previously. 

The  fire  should  also  be  serviced  annually  by  a  competent  person:  Gas  Safe  ™  registered  installer 
(formerly CORGI) in the UK. This is best done before the heating season. 

NOTES 
 

The first time that the appliance is used, there will be some odour produced due to the newness of 
the materials. It is recommended that the unit is fired at maximum setting for several hours and 
the  room  is  kept  ventilated  during  this  period.  It  is  usual  for  flueless  appliances  to  produce  an 
initial odour after start up. 
If  the  pilot  flame  should  ever  extinguish  of  its  own  accord,  ventilate  the  room  and  allow  a 
minimum of 5 minutes before relighting.  
 
Never attempt to relight the unit if there is a gas smell, ventilate the room first. 
 
If the unit continues to extinguish after a period of use, do not use it and seek the advice of your 
installer. 

 
GENERAL 

 
To qualify for your free second year guarantee, you must fully complete and return the separate 
Guarantee  Card.  There  are  sections  that  your  fitter  must  complete  whilst  he  is  fitting  the  fire.  If 
the fully completed Guarantee  Card is not returned within 7 days of fitting, the appliance is just 
covered by the standard 12 month guarantee. 
 
As with all gas appliances, this fire MUST be serviced at least every 12 months, preferably at the 
start of the heating season. The second year guarantee is conditional on this service taking place. 
Servicing must be carried out by a qualified service engineer. 
 

BURLEY APPLIANCES ARE THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY 
SINGLE  GAS  FIRE  IT  PRODUCES.  BURLEY  ARE  IN  THE  UNIQUE  POSITION  OF  KNOWING  THAT 
EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER. 
 

Содержание G4237 IMAGE

Страница 1: ...Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4237 8InstUser G20 31 Issue March09 v 3 TO OBTAIN YOUR FIRST YE...

Страница 2: ...lbow 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and also with just the Burley heater operating If outside of this tolerance the fault...

Страница 3: ...lled in high rise blocks of flats bed sitting rooms basements which are not open on at least one side bathrooms or bedrooms in corridors stairways landing or hallways of multi occupancy dwellings gara...

Страница 4: ...the top surface standing a minimum of 50mm above surrounding floor level or surrounded by a raised fixed fender of 50mm high The hearth must extend a minimum of 100mm in front of the fire bed and 50m...

Страница 5: ...s are of the correct type Use all 6 screw holes in the brackets to attach to the wall If the appliance is hearth mounted the fixing is intended to prevent the appliance from moving toppling and it is...

Страница 6: ...they have a minimum heat rating of 150o c Consideration should be given to the effect of expansion and contraction caused by temperature and back panels should be allowed to float or attached with a...

Страница 7: ...erature The case can be test fitted to the chassis to ensure clearance The gap in the case top between grille and spacer slides over the top flange on the appliance The bottom of the case has folded o...

Страница 8: ...ry pack and also explain that the batteries are not covered by warranty A handheld remote control is included in the box and this has a 9 volt battery to power it The battery should be changed annuall...

Страница 9: ...the main burner will not light check the thermostat position and if necessary select a warmer setting 9 2 To light the fire first ensure the red knob is turned clockwise to OFF Press the left hand red...

Страница 10: ...tally friendly manner Replacement rechargeable batteries for the fire and replacement handsets are available from Burley Appliances on 01572 756956 or through your retailer The 9 volt handset battery...

Страница 11: ...ormance and could lead to a hazard 10 4 FIREFRONTS The design of these affects combustion therefore only the correct front supplied with the appliance may be fitted 10 5 FIREGUARDS A fireguard is not...

Страница 12: ...t to the gas supply Test all joints for leaks Following the manufacturer s instructions re lay the fuel bed and replace the glass Light the fire using the method in the instructions and ensure that th...

Страница 13: ...athrooms bedrooms in corridors stairways landings or hallways of multi occupancy dwellings in garages or rooms containing petroleum products The guard on the appliance is to prevent risk of fire or in...

Страница 14: ...eater in which case they will select a flame height on the red knob then set the thermostat black knob to a comfort level In both cases if the room gets too hot the thermostat will automatically reduc...

Страница 15: ...about 20 seconds and then it will light the burner on high flame 6 To alternate between high and low flame use the flame buttons on the right hand side of the handset 7 To turn the fire OFF press the...

Страница 16: ...appliances to produce an initial odour after start up If the pilot flame should ever extinguish of its own accord ventilate the room and allow a minimum of 5 minutes before relighting Never attempt t...

Страница 17: ...67 and the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at...

Страница 18: ...sult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filte...

Страница 19: ...is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertai...

Страница 20: ...the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe re...

Отзывы: