Electrical installation
9
ELECTRICAL INSTALLATION
All electrical inputs and outputs of the device are
not
galvanically
isolated from the supply voltage.
9.1
Safety instructions
DANGER!
Risk of electric shock.
▶
Before working on equipment or device, switch off the power
supply and secure to prevent reactivation.
▶
Observe applicable accident prevention and safety regulations
for electrical equipment.
WARNING!
Risk of injury from improper installation.
▶
Installation may be carried out by authorized technicians
only and with the appropriate tools.
Risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶
Secure system from unintentional activation.
▶
Following installation, ensure a controlled restart.
9.2
Electrical installation without fieldbus
communication
→
Connect the positioner according to the table.
6
1
7
5
4
3
2
8
Fig. 9: Circular plug M12 x 1, 8-pin
Input signals of the control center (e.g. PLC)
Pin Wire
color
5)
Configuration
External circuit, signal level
1
2
white
brown
Set-point value +
(0/4 – 20 mA)
Set-point value
GND
1
2
+ (0/4 – 20 mA)
GND
see table connection
type 3-wire or 4-wire
5
6
grey
pink
Digital input +
Digital input GND
5
+
0 – 5 V (log. 0)
10 – 30 V (log. 1)
6
GND
Tab. 3: Pin assignment, input signals of the control center