Technical data
6.6
Type labels
6.6.1
Type label (example)
8696 -E1-...-0 PU02
Single act Pilot 0.6 24V
Pmax 7 bar
Tamb -10 - +60 °C REV.2
S/N 1001
00123456
D-74653
Ingelfingen
W15MA
Order number, manufacture code
Max. operating pressure
Type, features of the type code applicable to
UL and ATEX
Control function, pilot valve,
supply voltage pilot valve
Barcode
Serial number; CE marking
Ambient temperature, version
Fig. 4: Type label (example)
6.6.2
UL additional label (example)
Degree of protection
Circuit with limited power
Communication,
supply voltage
Type 4X enclosure
NEC Class 2 only
Power Supply: büS
24V ±25%
max. 3,5 W
Power consumption
E238179
Fig. 5: UL additional label (example)
6.7
Pneumatic data
Control medium neutral gases, air
Quality classes in accordance with ISO 8573-1
Dust content Class 7 max. particle size 40 µm,
max. particle density 10 mg/m³
Water content Class 3 max. pressure dew point
-20 °C or min. 10 °C below the
lowest operating temperature
Oil content
Class X max. 25 mg/m³
Temperature range
-10 – +50 °C
Pressure range
3 – 7 bar
Air output of pilot valve:
7 l
N
/min (for aeration and deaeration)
(Q
Nn
value according to definition
for pressure drop from 7 to 6 bar
absolute)
Connections:
23xx / 2103 (Element)
Plug-in hose connector
∅
6mm / 1/4“
Socket connection G1/8
Model third-party device Socket connection G1/8
with M5 connection for connecting
to the third-party device