24
Installation
set mechanical end position limit (drives 100 - 1 000 nm)
8.2.2.
The mechanical end position limits have been preset at the factory and glued on with Loctide. However,
they can be adjusted by turning the screws M8 Pos. 17 (see
Fig. 2:Exploded view of motor 100 - 300
Fig. 3:Exploded view of motor 600 - 1 000 Nm
). Then the nuts must be glued on again.
Loosen the M8 nuts on the mechanical limit stops
→
17 (see Figs. 2/3) and adjust the mechanical end position
limits.
Glue nuts on again with Loctide (e.g. Loctide 577).
→
adjusting limit switch contacts
8.2.3.
The two upper limit switch contacts have been set to 0 - 90° at the factory.
removing position indicator and hood
Fig. 10: Removing glass hood
Fig. 11: Removing position
indicator
Fig. 12: Removing hood
procedure:
Remove glass hood of the position indicator 1 including the sealing ring by loosening the four fastening screws
→
and remove the glass hood (see
).
Remove position indicator (see
→
Fig. 11:Removing position indicator
Remove hood 2 by loosening the four fastening screws 3 (see
→
english