17
Technical Data
7.
TEChniCal DaTa
operating Conditions
7.1.
permitted temperatures
Ambient temperature:
-20 °C ... +70 °C
Permitted air humidity:
<70 %
Permitted application area: 0 - 2,000 m height
Protection class:
IP67 in accordance with EN 60529 with cable bushing ISO 20 or protective
flap
noTe !
Avoid heat sources which may result in the permitted temperature range to be exceeded.
•
Conformity
7.2.
CE mark conforms to EMC Directive 204/108/EEC (only if cables, plugs and sockets connected correctly).
general Technical Data
7.3.
mechanical Data
7.3.1.
Dimensions:
Weight:
25 -75 Nm; 3.1 kg
100 - 300 Nm; 5.6 kg
600 - 1,000 Nm; 20 kg
Housing material:
Cover and housing made of nylon
Axles and screws made of stainless steel
Gears made of galvanised steel
Actuating angle:
90° (optional 180°, 270°) ± 5°
Duty cycle:
50 % at maximum torque (optionally 80 %)
Manual emergency actuation: with open-end wrench on faces of the axle (up to 75 Nm);
by handwheel (from 100 Nm)
Working modes:
Open/Closed mode or Three points mode (see
Fig. 23:Open / Closed mode / Emergency current model