BREW COUNTERS
This function allows the operator to track the
number of brew cycles completed on the left side, the
right side, and the total of both combined. There are
three resettable counters, and one life counter that is
not resettable.
Procedures to view/reset the brew counters
:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES
. Release the ®. Press and
release the ® pad until the display reads
BREW
COUNTERS
.
2. Pressing
NO
in this screen will advance to the next
function. Press
YES
to view the first brew counter
(left). This number represents the brew cycles
initiated since that counter was last reset.
3. To advance to the other counters, press and re-
lease
NEXT.
The four counters are as follows:
LEFT -
total brews on the left side (resettable)
RIGHT -
total brews on the right side (resettable)
LEFT AND RIGHT -
total brews on the left and right
sides combined (resettable)
LEFT AND RIGHT -
total brews on the left and right
sides combined (non-resettable)
4. To reset any of the counters to zero (except for the
non-resettable counter), press and release
RESET
when viewing that particular counter's screen.
P2308
FUNNEL DETECT ?
Procedure to set funnel lockout:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES
. Release the ®. Press and
release the ® pad until the display reads
FUNNEL
DETECT
.
2.
NO
or
YES
should be flashing to indicate the
current setting.
4. Select
YES
to prevent brewing if a Smart Funnel
®
is not correctly situated in the rails. If this function
is activated and a brew cycle is attempted with the
funnel not properly situated, the display will read,
FUNNEL NOT IN PLACE
, until one is in place.
5. Select
NO
to allow brewing without a Smart Fun-
nel
®
in place. This is selected when brewing with
a funnel other than a Smart Funnel
®
(a regular
brew funnel).
6. When finished, press and release
DONE
. This will
retain the changes, exit this function screen and
advance to the next. Another alternative is to press
either of the
pads located on the front switch
panel to exit the
FUNNEL DETECT
and return to the
MAIN SCREEN.
P2309
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
5. When finished, press
NEXT
to advance counter
screens until the display reads
BREW COUNTERS.
Press and release
NO
to advance to the next
function screen, or press and release either of the
pads on the front switch panel to exit the
BREW COUNTERS
function and return to the
MAIN
SCREEN.
FUNNEL LOCKOUT
This function allows the operator to prevent the
start of a brew cycle if a Smart Funnel
®
is not posi-
tioned correctly in the funnel rails.
35058 121102
Содержание Single TF DBC
Страница 89: ...Página 48 35058 80 050803 ...
Страница 90: ...Página 49 35058 80 050803 ...
Страница 112: ...Page 22 SET PULSE BREW cont PROGRAMMING FUNCTIONS LEVEL 2 cont 35058 121102 ...
Страница 151: ...10 DUAL TF TANK AND MOUNTING BRACKETS 1 2 3 4 5 P2617 45 35060 021808 7 6 8 9 10 Late Models 1 ...
Страница 157: ...16 DUAL TF INLET VALVE AND LINE 2 1 3 4 5 6 P3951 35060 021412 7 9 10 11 6 9 8 5 7 230 Volt Models ...
Страница 161: ...20 DUAL TF FAUCET P2620 75 2 3 4 5 6 8 7 9 1 11 10 14 15 35060 111307 11 10 12 13 14 1 Faucet W Barb Fitting ...
Страница 169: ...28 DUAL TF 7 2 3 5 6 4 8 9 1 FUNNEL P2340 50 35060 121502 ...