Page 27
COPY SETTINGS (NO NAME COFFEE SETTINGS ONLY)
This function is used to transfer all the brew
settings from a
NO NAME
coffee flavor programmed
on one side of the brewer to the other side. A
NO NAME
coffee is a flavor that is not in the grinder's memory or
is what appears if a Smart Funnel
®
is not used.
For example, once the left side's 3 batch sizes are
programmed (brew volumes, bypass percentages,
pulse brew times, pre-infusion times, and drip-out
times) for a particular
NO NAME
coffee, all the data can
be transferred from the left side of the brewer to the
right side in one step. The data can also be transferred
from right to left, if the right side had been the initial
set-up side. This results in less set-up time.
If two different
NO NAME
setups are required, one
on the left, the other on the right side, it is not
recommended that this function be used.
Procedure to copy settings:
1. Press and hold the ® pad until the display reads
SET RECIPES
. Release the ® pad. Continue to
press and release the ® pad until the display reads
COPY SETTINGS.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
P2298
2. Press
YES
in this screen. The display should read
LEFT >>> RIGHT
.
3. If the initial programming was done on the left side
of the brewer, press
YES
. The display will read
ARE
YOU SURE?
4. If you are sure that the data should be transferred
from left to right, press
YES
. The display will then
read
TRANSFER COMPLETE
, and will automati-
cally advance to the next function screen.
5. In the
LEFT >>> RIGHT
screen, if the program-
ming was done on the right side and it is desired
to transfer from right to left, press
NO
. The display
will then read
LEFT <<< RIGHT
.
6. If the initial programming was done on the right
side of the brewer, press
YES
. The display will read
ARE YOU SURE?
7. If the data should be transferred from right to left,
press
YES
. After the data is transferred, the
display will read
TRANSFER COMPLETE.
This will
appear for 3 seconds, then will exit to the next
function screen. Brew settings for all flavors are
not the same on both sides of the brewer, only the
NO NAME
setting has been transferred.
35058 121102
Содержание Single TF DBC
Страница 89: ...Página 48 35058 80 050803 ...
Страница 90: ...Página 49 35058 80 050803 ...
Страница 112: ...Page 22 SET PULSE BREW cont PROGRAMMING FUNCTIONS LEVEL 2 cont 35058 121102 ...
Страница 151: ...10 DUAL TF TANK AND MOUNTING BRACKETS 1 2 3 4 5 P2617 45 35060 021808 7 6 8 9 10 Late Models 1 ...
Страница 157: ...16 DUAL TF INLET VALVE AND LINE 2 1 3 4 5 6 P3951 35060 021412 7 9 10 11 6 9 8 5 7 230 Volt Models ...
Страница 161: ...20 DUAL TF FAUCET P2620 75 2 3 4 5 6 8 7 9 1 11 10 14 15 35060 111307 11 10 12 13 14 1 Faucet W Barb Fitting ...
Страница 169: ...28 DUAL TF 7 2 3 5 6 4 8 9 1 FUNNEL P2340 50 35060 121502 ...