![Bunn Single TF DBC Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/bunn/single-tf-dbc/single-tf-dbc_installation-and-operating-manual_2831094113.webp)
Page 23
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
Setting Pulse Brew - BY EXAMPLE:
1. This display should read
CONTAINER READY?
Place a container under the left side sprayhead.
Place a brew funnel containing a filter and grounds
on top of the container so that the spray and cof-
fee bed can be viewed. (See Fig. 1)
2. Choose the batch size to be set by pressing the
pad next to the indicator light on the left brew side.
The batch size indicator selected will be flashing.
3. If everything is in place, press YES in the
CON-
TAINER READY?
screen. The display should read
PRESS BREW TO START 1ST ON TIME. (a)
4. Press and release the
pad. The brew water
will start to flow into the funnel and the water level
will rise.
(b)
5. Watch the flow of water. When it reaches the de-
sired level in the funnel, press and release the
pad again to end the
1ST ON TIME. (c)
6. The spray will stop and the brew funnel will start
to empty. When the water level in the funnel drains
to the desired level, press
again to end the
OFF-TIME
. This also begins the spray of water for
the final setting.
(d)
7. The brew water will begin again and the water level
in the funnel will rise. Watch the flow of water.
When it reaches the desired level, press
to
end the
LAST ON TIME. (e)
8. The display should now show the 1st, off and last
times for the batch size just programmed. After a
5 second delay, the display will read
3 BATCHES
DONE? (f and g)
9. If other batches need to be modified, press
NO.
The display will go back to
SET BY EXAMPLE.
Press
YES
, then press a different batch size pad
and repeat steps 1 through 8. Repeat until all the
desired batch sizes are set for the left side.
(g)
10. When finished press
YES
in
3 BATCHES DONE?.
The display will then read
SET PREINFUSION.
Another alternative is to press and release either
of the
pads located on the front panel of the
brewer to exit
SET PULSE BREW
and return to
the
MAIN SCREEN
.
NOTE:
Pressing ® before reaching the final setting
screen exits the setup and retains the old values.
P2613
FIG. 1
P2410
35058 121102
Содержание Single TF DBC
Страница 89: ...Página 48 35058 80 050803 ...
Страница 90: ...Página 49 35058 80 050803 ...
Страница 112: ...Page 22 SET PULSE BREW cont PROGRAMMING FUNCTIONS LEVEL 2 cont 35058 121102 ...
Страница 151: ...10 DUAL TF TANK AND MOUNTING BRACKETS 1 2 3 4 5 P2617 45 35060 021808 7 6 8 9 10 Late Models 1 ...
Страница 157: ...16 DUAL TF INLET VALVE AND LINE 2 1 3 4 5 6 P3951 35060 021412 7 9 10 11 6 9 8 5 7 230 Volt Models ...
Страница 161: ...20 DUAL TF FAUCET P2620 75 2 3 4 5 6 8 7 9 1 11 10 14 15 35060 111307 11 10 12 13 14 1 Faucet W Barb Fitting ...
Страница 169: ...28 DUAL TF 7 2 3 5 6 4 8 9 1 FUNNEL P2340 50 35060 121502 ...