20
ENABLE ENERGY SAVER
This function allows the operator to enable the ENERGY
SAVINGS mode function and set the idle time. Once
the set idle time has expired, the operator can choose
to have the heaters
either turn off, or reduce the tank
holding temp to 140° F (60° C).
Procedure to enable energy savings mode:
Range: 0.5 to 24.0 hrs
If enabled, default setting is 140° F (60° C) tank
temperature after 4.0 hrs. idle time.
1.
Press and hold the right hidden button until the
display reads
RECIPES.
Press the right hidden
button until the display reads
SETTINGS
, then press
SELECT
.
Press and release the right hidden switch
until the display reads
ENABLE ENERGYSAVR
. The
YES
or
NO
will be flashing to indicate the current
selection.
2. Select
NO
to disable or:
3. Select
YES
to enable this function.
4. When finished, press and release
DONE
to save the
new setting and advance to the next screen.
5. If
NO
was selected, the display should now read
EnableFreshTimer
. To exit programming and return
to the
MAIN SCREEN
, press
ENABLE BREW ON/
OFF
switch.
6. If
YES
was selected, the display should now read
X.X HRS -> IDLE
. This screen allows the operator
to set the amount of time the brewer is not in use
before energy save mode engages. Using
(-)
and
(+)
,
adjust the idle time. When finished, select
DONE.
7. The display should now read
AFTER IDLE TIME?
Once the set idle time has expired, the heaters can
either be shut off or held at 140° F.
8. To have the heaters shut off after the set idle time,
select
OFF
and then
DONE
to save the settings.
The display should read
MACHINE OFF AFTER X.X
HRS,
and then
EnableFreshTimer.
9. To have the temperature reduce to 140° F, select
140°
and then
DONE
to save the settings. The display
should read
MACHINE AT 140° AFTER X.X HRS
,
and then
EnableFreshTimer.
10. Once the idle time has expired, the display will
read either
ENERGY SAVER...NO TEMPERATURE
or
ENERGY SAVER...REDUCED TEMPERATURE
,
depending on the settings. This screen will alternate
with
PRESS ANY SWITCH TO RE-HEAT
.
ENABLE FRESH TIMER
This function allows the operator to enable the Fresh-
ness Alert and set the expiration time. The expiration
time is the amount of time the product is allowed to sit
in the server/dispenser before a fresh batch is brewed.
Procedure for enabling/setting the Freshness Timer:
Range: Coffee 0.5 to 4.0 hrs
Hot Tea 0.5 to 8.0 hrs
If enabled, default setting is 2.0 hrs. for Coffee and 2.0
hrs. for Hot Tea.
1.
Press and hold the right hidden button until the
display reads
RECIPES.
Press the right hidden
button until the display reads
SETTINGS
, then press
SELECT
.
Press and release the right hidden button
until the display reads
ENABLE FRESHTIMER
.
2. Select
NO
to disable or:
3. Select
YES
to enable this function (the unit will
display a message once the set time has expired).
4. When finished, select
DONE
to save the new setting
and advance to the next screen.
5. If
NO
was selected, the display should now read
REFILL
. To exit programming and return to the
MAIN SCREEN
, press either
ENABLE BREW ON/
OFF
switch.
6. If
YES
was selected, the display should now read
COFFEE
. This screen allows the operator to set the
amount of time from the end of brewing a batch
of coffee until a Freshness Alert message will be
displayed. Using
(-)
and
(+)
, adjust the freshness
time for coffee. When finished, select
DONE.
7. The display should now read
HOT TEA
. Using
(-)
and
(+)
, adjust the freshness time for hot tea. When
finished, select
DONE.
8. This display should now read
REFILL.
To exit
programming and return to the
MAIN SCREEN
,
press
ENABLE BREW ON/OFF
switch.
9. Once the set time has expired, the display will
read
FRESHNESS ALERT BREW (A,B or C)
, and
then
FRESHNESS ALERT BREW FRESH BATCH
alternating with the
MAIN SCREEN
.
10. Empty the server/dispenser the previous batch was
brewed into and replace under the funnel.
11. Brew a new batch
12. The freshness timer will reset. The display should
now return to the
MAIN SCREEN
.
PROGRAMMING FUNCTIONS (cont.)
PROGRAMMING BREWER
(cont.)
(cont.)