Bunn ICB SH Скачать руководство пользователя страница 18

18

ENABLE ADS

This function allows the operator to choose whether 

or not to display an advertising message. An ad can be 

saved to the brewer by either writing the ad using the 

programming commands, or by entering the ad into 

the brewer using an 

AD CARD

. This message will be 

displayed when the brewer is not in use.

Procedure to Enable/Disable Ads:

1.  Press and hold the right hidden button until the 

display reads 

RECIPES. 

Press the right hidden 

button until the display reads

 SETTINGS

, then press 

SELECT

. Press the right hidden button until the 

display reads 

ENABLE ADS

. The 

YES

 or 

NO

 will be 

flashing to indicate the current selection.

2. Select 

NO

 to disable this function, or:

3. Select 

YES 

to enable this function.

4.  When finished, select 

DONE

 to save the new setting 

and advance to the next function screen.

5. If 

NO

 was selected, the display should now read 

ENABLE SANITATION

. To exit programming and 

return to the 

MAIN SCREEN

, press 

ENABLE BREW 

ON/OFF

 switch.

6. If 

YES

 was selected, the display should now read 

NEW AD?

. This screen allows the operator to select 

between using an ad card to 

read

 in a new ad, or 

writing

 an ad through the control panel.

Procedure to WRITE an Ad:
NOTE: 

Writing and saving a new ad will erase any 

previously saved ad in the brewer’s memory.

7.  From the 

NEW AD? 

screen, select 

WRITE

.

8.  The display should now read 

2 LINES 16 CHARS 

AVAILABLE

, and then 

SCROL THRU ALPHA, NEXT 

-> NEXT LETTER, 

and then

 WRITE TOP LINE?

. The 

ad can be up to 32 characters long, 16 per line. The 

ad will be written in two steps, first the top line, 

then the bottom line.

9.  To write the top line of a new ad, select 

YES. 

To skip 

the top line and only write a bottom line, select 

NO 

and proceed to step 13.

10. The display will now read 

A

 with a flashing cursor 

below it. Press the 

SCROLL

 button to scroll through 

the alphabet and available characters. When the 

desired character is shown on the display, select 

NEXT 

to move to the next character in the top line.

PROGRAMMING FUNCTIONS (cont.)
SET TEMP - 

ICB SH/ICB TWIN SH

This function allows the operator to adjust the brew 

water temperature in the tank. This also sets the hot 

water faucet dispense temperature.

Procedure for setting the Set Temp

Range: 185° to 205° F (85° - 96° C)

1.  Press and hold the right hidden button until the 

display reads 

RECIPES. 

Press the right hidden  

button until the display reads

 SETTINGS

, then 

press 

SELECT

. Press the right hidden button until 

the display reads

 SET TEMP

.

2. Using 

(-)

 and 

(+)

, adjust the brew and faucet  

temperature.

3.  When finished, press and release 

DONE

 to save 

the new setting and to advance to the next function 

screen, 

READY DEGREE

. Press 

ENABLE BREW ON/

OFF

 switch to exit programming and return to the 

MAIN SCREEN

.

READY DEGREE

This function allows the operator to set the minimum 

temperature allowable to start a brew cycle. The range 

can be from 2° to 20° F below the set temperature. The 

water must be at the 

READY

 temperature or higher 

for the display to indicate 

READY TO BREW

. If brew 

lockout is enabled, the brewing process will not start 

below this 

READY 

temperature.

Procedure to set ready temperature

Range: 2° to 20° F (2° to 10° C) below set temp

1.  Press and hold the right hidden button until the 

display reads 

RECIPES. 

Press the right hidden  

button until the display reads

 SETTINGS

, then 

press 

SELECT

. Press the right hidden button until 

the display reads

 READY DEGREE

.

2. Using 

(-)

 and 

(+)

, adjust the ready temperature.

3.  When finished, select 

DONE

 to save the new setting 

and to advance to the next screen, 

ENABLE ADS

Press 

ENABLE BREW ON/OFF

 switch to exit.

PROGRAMMING BREWER 

(cont.)

(cont.)

Содержание ICB SH

Страница 1: ...Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates F...

Страница 2: ...en do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equip...

Страница 3: ...sturdy counter or shelf The Infusion Series combines BrewWISE and CDBC into one ICB SH and ICB Twin SH are able to brew coffee with recipe settings They have an LCD for digital readout and programming...

Страница 4: ...Ads Disabled Disabled Enable Sanitation Disabled Disabled Enable Energy Saver Disabled Disabled Enable Fresh Timer Disabled Disabled Refill 155 155 Left Spray Oz X 40 0 Right Spray Oz X 41 0 Spray Oz...

Страница 5: ...5 Server Detect Enabled Enabled SH Empty Detect Enabled Enabled SH Heat Auto Off Disabled Disabled Server Preheat Enabled Enabled Server Indicators Enabled Enabled FACTORY DEFAULTS cont ICB ICB TWIN...

Страница 6: ...NEW RECIPE CALIBRATION SPRY HEAD CAL BYPASS CAL L SPRY OZ M XX X L BYPS OZ M XX X R SPRY OZ M XX X R BYPS OZ M XX X SETTINGS SERVICE SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT DON...

Страница 7: ...EL DETECT SERVER DETECT SH EMPTY DETECT SH HEAT AUTO OFF SERVER PREHEAT ENABLE FRESH TIMER ENABL ENERGYSAVR ENABL ADS BREW ALERT SERVER INDICATORS SERVICE SELECT SELECT METRIC DONE ENG SELECT COLUMN A...

Страница 8: ...TPUTS TEST SWITCHES TEST FREQUENCY ENTER ASSET ENTER SERVICE BREW COUNTERS SELECT SELECT SELECT SELECT SELECT SELECT SELECT COLUMN B X REFILL XXX DONE FACTORY DEFAULTS NO YES PROGRAMMING FUNCTIONS FLO...

Страница 9: ...ect press SAVE The display will read AD MESSSAGE SETUP COMPLETE The ad is now stored in the brewer s memory 6 If the ad is not correct or it is desired to exit the setup before the ad is loaded into t...

Страница 10: ...e level 2 function screens press and hold the right hidden button for approximately 5 seconds Release when the display reads SET LANGUAGE This function allows the operator to select the language used...

Страница 11: ...will be different ex Brew oz will become Brew liters Temperature changes from F to C REVIEW RECIPES Modify or Show recipes This function has two parts 1 It allows the operator to view the brew settin...

Страница 12: ...ll return to the recipe name just viewed 4 To see the settings again select SHOW To change settings select MODIFY Then the screen will display BREW OZ and a batch light will be blinking 5 Using or set...

Страница 13: ...ULSEBREWDISABLED After a 5 second delay the display will read 3 BATCHES DONE INITIAL SPRAY INITIAL SPRAY ALTERNATES UNTIL BREW CYCLE IS COMPLETED PRE INFUSION REMAINING ON ON TIME OFF TIME OFF TIME OF...

Страница 14: ...ch sizes and repeat step 27 29 When finished setting all batch sizes press and release DONE The display should read 3 BATCHES DONE 30 The display will read SH TEMP XXX 31 Using or set temp for SH Serv...

Страница 15: ...D REVIEW RECIPES SET PULSE BREW DRIP TIME 0 30 SELECT METHOD NO NAME COFFEE BREW OZ 64 BYPASS 20 SH TEMP XXX FRESH X XX HRS NO YES NO YES DONE EASY MANUAL MODIFY SHOW NEXT DONE DONE DONE DONE PROGRAMM...

Страница 16: ...tored recipes in the brewer s memory until the desired recipe name is reached 7 Select DONE to set that recipe for brew switch B 8 ThedisplayshouldnowreadSELECTRECIPEBREW SWITCH C and then BREAKFAST B...

Страница 17: ...with a NO and YES If the name on the display is correct press YES 6 If for some reason the name of the coffee from the grinder did not load properly into the funnel or if a grind has not yet been don...

Страница 18: ...proceed to step 13 10 The display will now read A with a flashing cursor belowit PresstheSCROLLbuttontoscrollthrough the alphabet and available characters When the desired character is shown on the di...

Страница 19: ...SAVED and then will return to the NEW AD screen 19 To correct or edit the ad select EDIT The display should now read WRITE TOP LINE Repeat steps 10 though 17 20 To save the ad as it is shown select YE...

Страница 20: ...REDUCED TEMPERATURE dependingonthesettings Thisscreenwillalternate with PRESS ANY SWITCH TO RE HEAT ENABLE FRESH TIMER This function allows the operator to enable the Fresh ness Alert and set the exp...

Страница 21: ...til the display reads CALIBRATION then press SELECT Press and release the right hidden switch until the display reads SPRY OZ M The number represents what the brewer thinks is the flow rate out of tha...

Страница 22: ...1 7 to calibrate the other side 9 To exit the CALIBRATE FLOW function and advance to the next screen select NO To exit programming and return to the MAIN SCREEN press either ENABLE BREW ON OFF switch...

Страница 23: ...om pleted This counter is non resettable Press NEXT to advance to the next brew counter BREW A left side 3 This counter represents the number of brews for Brew A on the left side of the brewer To rese...

Страница 24: ...to the next digit in the phone number 4 Repeat Step 3 until the entire number is entered 5 Press and release DONE The display will now read BREW COUNTERS SERVICE FOR AUTHORIZED SERVICE PERSONNEL ONLY...

Страница 25: ...is saving the settings to your brewer When completed the screen will read SAVE COMPLETE REMOVE DRIVE Procedure for loading new software versions into brewers 1 Place new software file from computer o...

Страница 26: ...ermanent If an intermittent condition is encountered the cause will likely be a switch contact or a loose connection at a terminal or crimp Solenoid removal requires interrupting the water supply to t...

Страница 27: ...re Sensor Probe wire s broken or not making connection 1 Temperature Sensor Probe wire s shorted to housing or to each other 1 No power or incorrect voltage A Wait for the brewer to heat to the proper...

Страница 28: ...ck Test the ON OFF switch Test the BREW switch Test the brew valve Substitute a control board known to be in good working order Checkplumbingandshut offvalves 1 No water 2 No power or incorrect voltag...

Страница 29: ...igh mineral content high conductance water requires a lower setting Note that theleftnumberchangesfromahigh value when water is NOT touching the refill probe to a low valve when waterIStouchingtheprob...

Страница 30: ...the refill solenoid Connect the brewer to the power source Press theON OFFswitchtoturnthebrewer on Within five seconds voltage should be present at the solenoid terminals If voltage is not present ref...

Страница 31: ...ed on to fill the tank The right number is the threshold setting and can be adjusted to compensate for ex treme water conditions very pure low conductance water requires a higher setting while high mi...

Страница 32: ...ng should be 15 3k 2k OHMS at 70 F 21 C the reading should be 11 8k 2k OHMS and at 80 F 27 C the reading should be 9 3k 2k OHMS If the probe is withintheseparameters reconnect to the control board Rem...

Страница 33: ...bath of approximately 70 F 21 C Connect an ohmmeter to the pins in the connector At 60 F 16 C the reading should be 15 3k 2k OHMS at 70 F 21 C the reading should be 11 8k 2k OHMS and at 80 F 27 C the...

Страница 34: ...me buildup If bypass is being used on the in consistent brewing recipe test the bypassvalve Refertotestoutputs Turnthevalveonfor30secondsand collect the water collected from the funnel Repeatthetestse...

Страница 35: ...for each brew cycle The mounting screws on the so lenoids must be tight or they will vibrate during operation Plumbinglinesshouldnotberesting on the countertop The brewer must be connected to a cold w...

Страница 36: ...ndthebedof grounds leveled by gently shaking Empty the server remove its cover and place the server beneath the sprayhead Placeemptyfunnelover theserverentrance notinthefunnel rails Press brew Check t...

Отзывы: