background image

Bullard TI Commander™ Thermal Imager

User Manual

P

alm and T

op Str

aps

5

Palm and Top Straps

The palm and top straps 

(Item 12, 13, Figure 1)

are

designed to allow the user to replace the top and side strap
without having to return the unit to the factory.

Replacing the Palm Strap

Using a 3/8" wrench, remove the nut on the right side of
the strap. Remove the strap from the screw by lifting away
from the camera. Remove the left side of the strap by
removing the screw with a Phillips screwdriver. The new
strap should be attached by first securing the left bracket
to the camera using the existing screw. The right bracket
should then be secured by placing the bracket on the screw
and tightening the nut. The strap is correctly attached when
the Bullard logo or custom lettering is facing outward.

Adjusting the Palm Strap

To adjust the palm strap on the side of the unit, pull open the
leather hand guard and readjust the strap. Once adjusted to
comfortable length, close the leather hand guard.

Adjusting the Shoulder Strap

To attach the shoulder strap, clip the hooks to any of the
three D-rings on the unit. Adjust the strap to a comfortable
length.

Replacing the Top Strap

Unwrap the leather pad from the strap to expose the ends
of the strap. Remove the right side of the strap from the
Velcro. Wrap the end around the anchor on the top of the
camera and re-attach to the Velcro. Remove the left side of
the strap from the Velcro, wrap the end around the anchor
on the top of the camera and re-attach to the Velcro. Wrap
the leather pad around the strap ends.

Wrist Strap

This strap can be used as a backup to keep the imager from
falling if it should slip from your hand. The adjustable strap
fits over the sleeve of your turnout gear and can adjust to
any size wrist. The wrist strap can be easily attached to any
D-ring located on the camera.

Top Strap

Palm Strap

Wrist Strap

Содержание TI Commander

Страница 1: ... a firefighting tool encompass just about every aspect of a firefighter s job Thermal imaging is not however a technology designed to replace current firefighting tactics Rather it is a tool that allows the firefighter to be more effective and make better decisions Some of the many uses for your Bullard Thermal Imager include Search and rescue Scene assessment Locating the seat of the fire Determi...

Страница 2: ... Optional On Off Sleep Button 1 2X Digital Zoom 5 Optional Battery Compartment 7 Charge and Data Output Port 11 LCD Screen Top Strap 12 Rear Boot Polycarbonate Display Cover 9 Lens Bezel 8 Bullard TI Commander Thermal Imager Figure 1 Thermal Throttle 2 Image Capture 4 Optional Palm Strap 13 ...

Страница 3: ...f the pupil in the eye When there is bright light the pupil shrinks When there is low light the pupil expands The Thermal Throttle works the same way In high heat situations the Thermal Throttle may be reduced down to obtain the best contrast and the clearest image In low heat situations theThermal Throttle should be wide open Since theThermalThrottle is manually adjusted the operator can always g...

Страница 4: ...ll illuminate on the charger to indicate that the battery is charging When the light on the charger turns to green the battery is fully charged You may leave the direct charge system in place indefinitely as the batteries will not overcharge Using the Direct Charge System Battery Charger A battery can be charged in the charger at the same time as the battery in the camera is being charged by using...

Страница 5: ...m strap on the side of the unit pull open the leather hand guard and readjust the strap Once adjusted to comfortable length close the leather hand guard Adjusting the Shoulder Strap To attach the shoulder strap clip the hooks to any of the three D rings on the unit Adjust the strap to a comfortable length Replacing the Top Strap Unwrap the leather pad from the strap to expose the ends of the strap...

Страница 6: ... and sides of the window Then remove the battery door thumb knobs by loosening the two screws that retain them Remove the plastic display cover and replace with a new one part numberTIWINDOW making sure that the O ring countersink slots around the mounting holes are facing outward When reinserting the screws make sure each one has the sealing O ring in place CAUTION Do not use solvents paint thinn...

Страница 7: ...vice for a period of one 1 year from date of manufacture Bullard s obligation under this warranty is limited to repairing or replacing at Bullard s option articles that are returned within the warranty period and that after examination are shown to Bullard s satisfaction to be defective subject to the following limitations a Article must be returned to Bullard with shipping charges prepaid b Artic...

Страница 8: ...er Includes Sony recorder 5 LCD screen two BATTERYNIMHULTRA batteries hard case and all necessary cables for receiving transmitted video signal MCC4 4 channel Mobile Command Center Includes 5 LCD screen two BATTERYNIMHULTRAbatteries hardcase andallnecessarycablesfor receiving transmitted video signal Sony recorder not included ML1 2 channel MobileLink handheld receiver Includes battery battery cha...

Отзывы: