R E S P I R ATO RY
This respirator is NIOSH-approved
(TC-19C-309) for Type C and CE
operations. It can be worn for general
purpose applications, including heavy-
and light-duty abrasive blasting, and
spray painting.
This respirator is not for use in any
atmosphere immediately dangerous
to life or health (IDLH), or from which
the wearer cannot escape without the
aid of the respirator.
H E A D
LANCER
™
respirators meet ANSI
Standard Z89.1-1969 (except weight)
Class A requirements for protective
headwear for industrial workers. The
helmet is designed to provide limited
head protection by reducing the force
of falling objects striking the top of the
helmet.
FAC E
The respirator’s inner window meets
ANSI Z87.1-1989 requirements for
face protection. When fitted with the
proper Bullard lens, it provides limited
face protection from flying particles or
spray of hazardous liquids, but is not
shatterproof.
E Y E S
LANCER respirators DO NOT provide
primary eye protection. Wear approved
safety glasses or goggles at all times.
H E A R I N G
LANCER respirators DO NOT provide
hearing protection. Use properly fitted
hearing protection when exposed to
high noise levels.
AIR QUALITY
WARNING
:
THIS RESPIRATOR
MUST BE SUPPLIED WITH CLEAN,
BREATHABLE AIR, GRADE D OR
BETTER, AT ALL TIMES. THIS RESPI-
RATOR DOES NOT PURIFY AIR OR
FILTER OUT CARBON MONOXIDE,
NITROGEN OR OTHER CONTAMI-
NANTS.
Respirable, breathable air must be
supplied to the point-of-attachment of
the approved Bullard air supply hose.
The point-of-attachment is where the
air supply hose connects to the fitting
that contains a pressure gauge used
to monitor the pressure of air provided
to the respirator wearer (see Figure 2
and Figure 3).
Supplied breathing air must AT
L E A S T meet the requirements for
Type 1 gaseous air as described in
the Compressed Gas Association
Commodity Specification G-7.1
(Grade D or higher quality), and as
specified by Federal Law 42 CFR,
Part 84, Subpart J, 84.141(b).
O P E R AT I O N S
FIGURE 2
Respirator
Air Supply
Hose
Point-of-
attachment
Pressure
Gauge
Grade ”D”
Breathable
Air Source
P ro t e c t i o n
Breathing Air Requirements
7
▲