SomnuSeal mask
Dear Customer,
The multi-use SomnuSeal™ Oral Mask allows a
single patient at home or multiple patients at a clinic
(hospital, sleeping lab, etc.) to undergo Positive Air
Pressure (PAP) treatment, provided that a physician
has prescribed PAP treatment.
The SomnuSeal™ is used to create the Positive Air
Pressure required to treat sleep apnea by
comfortably transferring air directly into the mouth in
order to keep the patient’s airways open.
Users can continue using their existing PAP
machine since the SomnuSeal™ can be connected
to any CPAP, Bi-level and Auto PAP machine, as
well as to any other PAP machine used to treat
sleep apnea.
Please read through and pay careful attention to
the following operating and maintenance
instructions.
Warnings indicate precautions and instructions
that may result in personal injury if they are not
followed.
Cautions indicate instructions that may result in
damage to the equipment or to the quality of
treatment if they are not followed.
Description
The intra-oral parts of the SomnuSeal™ mask are
made of medical grade silicone.
The SomnuSeal™ has four main parts:
1) main Body, 2) Strap Connector 3) Straps and 4)
SomnuSeal Air Vent (tube).
The strap connector (2) connects the body of the
mask (1) to both the straps (3) and the SomnuSeal
air vent (4), which connects in turn (at the other side)
to the PAP machine’s tube.
Package Contents:
1 SomnuSeal Mask (main Body)
1 Straps with Strap Connector
1 SomnuSeal Air Vent
The mask is offered in one size that fits all
.
Do NOT use the SomnuSeal™ if:
•
You have a known sensitivity to silicone.
•
You are incapable of removing the mask unaided.
•
PAP treatment was not prescribed to you by a
physician.
•
The PAP machine is not working properly.
•
The SomnuSeal air vent is blocked.
•
The mask provokes your gag reflex.
•
Always use a humidifier when using the
SomnuSeal™.
•
Always activate the PAP machine before placing
the mask in your mouth.
•
Always breathe through your mouth.
•
Never connect the SomnuSeal™ directly to the
PAP machine’s tube The SomnuSeal air vent must
be always positioned between them.
•
Never insert the mask into your mouth any further
in than the teeth.
User Guide
If you are new to using the SomnuSeal™
1.
The SomnuSeal masks require less air
pressure than traditional masks for the same
very good therapeutic result. Therefore the
recommended initial Auto PAP/Bi-level air
pressure setting:
lowest boundary air pressure: 3 or 4 cm H
2
O
(the lowest possible), highest boundary air
pressure 6 cmH
2
O.
In Continuous Positive Air Pressure (CPAP)
mode, set the air pressure level to 60% of the
original prescribed air pressure level (aimed at
traditional masks), not less than 5 cm H
2
O and
not more than 6 cm H
2
O – it is recommended to
CIRCLIFE