Use the location information for the failing part to activate the indicator light that identifies the failing part. For
instructions, see
Activate the indicator light for the failing part
Parent topic:
Identify a failing part on an AIX system or logical partition
Activate the indicator light for the failing part
The indicator light helps you locate which part to replace. To activate the indicator light, follow these steps:
Log in as root user.
1.
At the command line, type
diag
and press Enter.
2.
From the
Function Selection
menu, select Task Selection. Press Enter.
3.
From the
Task Selection
menu, select Identify and Attention Indicators. Press Enter.
4.
From the list of lights, select the location code for the failing part and press Enter.
5.
Select Commit. This turns on the system attention and indicator light for the failing part.
6.
Exit to the command line.
7.
Parent topic:
Identify a failing part on an AIX system or logical partition
Identify a failing part on a Linux system or logical partition
There are a number of methods to identify a failing part on a system or logical partition running Linux.
Locate a failing part and activate the indicator light
Use this task to locate a failing part if the service aids have been installed.
•
Activate the indicator light for the failing part
Use these instructions to activate the indicator light. The indicator light helps you locate which part to
replace.
•
Deactivate the failing-part indicator light
After replacing a failing part, use this task to deactivate the failing-part indicator light.
•
Identify a failing part using stand-alone diagnostics
Use this task if the operating system is stopped or if you need to stop the system or logical partition to
replace the failing part.
•
Parent topic:
Locate a failing part and activate the indicator light
Use this task to locate a failing part if the service aids have been installed.
To identify a failing part on a system or logical partition running Linux, you must locate the failing part, and
then activate the indicator light for that part.
Locate a failing part in a Linux system or logical partition
Use these instructions if you do not know the location code of the failing part. If you know the location
•
Control panel
Identify a failing part on an AIX system or logical partition
37
Содержание Escala PL 1650R-L+
Страница 1: ...Hardware Information Control panel ESCALA POWER5 REFERENCE 86 A1 30EW 00...
Страница 2: ...BLANK...
Страница 34: ...Control panel 28 Replace the control panel signal cable...
Страница 41: ...Control panel Stop the system or logical partition 35...
Страница 59: ...Control panel Open the model ESCALA PL 250R VL or ESCALA PL 450R XS service access panel 53...
Страница 83: ...Control panel Verify an installed feature or replaced part on an AIX system or logicalpartition 77...
Страница 89: ...BLANK...
Страница 90: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 30EW 00 REFERENCE...