Initial burner start-up
6
Buderus Blue Flame Burner BE 1.3 - 2.3 - Specifications subject to change without notice.
15
6
Initial burner start-up
This chapter describes how to start the burner for the
first time. The burner has been factory-fired, and set up
at the factory for room air independent operation. Verify
if the factory settings are acceptable for the installation,
and only adjust if required due to system specification.
z
Then complete the inspection log (see Chapter 6.9
„Installation protocol“, page 23).
6.1
Checking electrical plug connections
z
Verify that all electrical plug connections are correctly
installed.
6.2
Establishing combustion air pipe connection
In sealed combustion installations the flexible hose is
connected to the air intake in the blower housing.
z
Attach the flexible hose using the supplied hose
clamp.
6.3
Checking and connecting oil lines
Before connecting the oil supply to the burner, check
that all oil lines and the oil filter are clean and tight.
z
Inspect the oil lines including all components and
clean or replace if necessary.
z
Check oil filter, replace if previously used.
z
Check oil supply system (see Chapter 9 „Layout of oil
supply system“, page 36).
z
Connect burner oil hoses to a Tigerloop (supplied).
Fig. 8
Oil pump – Suntec
Item 1:
Oil suction line (red stripe)
Item 2:
Return line (blue stripe)
2
1
NOTICE
For safety reasons the burner is supplied
in "lock out status".
Fig. 9
Connecting flexible hose to burner
Item 1:
Supplied hose clamp
Item 2:
Flexible combustion air hose
2
1
NOTICE
Be careful not to reverse the suction and
return lines (Fig. 8).