Operating the Logamatic BC10 base controller
9
Logano GB125 oil condensing boiler - Technical specifications are subject to change without prior notice.
45
9.4
Set DHW temperature
With the rotary selector for "set DHW temperature", you can select the required
DHW cylinder temperature.
9.5
Status display and fault diagnostics
The BC10 base controller display indicates the state of the heating system.
In case of faults, the status display immediately indicates the relevant fault or a
warning.
Locking faults cause the status display to flash.
Press the "status display" key to change between the various status displays.
Status
Explanation
LED
0
Off
No DHW provision (only central
heating).
Off
Eco
Economy mode,
DHW temperature 60 °C
Not used on the Logano G135(T)
version.
On
30 – 60
Direct setting at the BC10
in °C
The temperature is permanently
set at the BC10 and cannot be
changed with a programming
unit.
On
Aut
Defaulted via the programming
unit
(pre-setting)
The temperature is set at the pro-
gramming unit (e.g. RC30). 60 °C
applies as DHW temperature if
no programming unit is connec-
ted.
On
Tab. 23 Setting options at the rotary selector for "set DHW temperature"